A technician has determined a supply in a flexible duct system is leaking. What should be checked? - ANSWERAll connections inner and outer layers. Electronic air cleaners can operate with internal voltages as high as? - ANSWER5000v Why do some electromechanical type thermostats require connections to both the hot side and common side of the low voltage transfromer - ANSWERDisplay lights must be powered using both sides of the line the continuity reading on a functional fuse will be - ANSWER0 ohms a compressor with proper voltage and a hard start relayt and capacitor draws lock rotor amps on startup. what is the problem? - ANSWER the technician believes that a hermetic compressor has a permanently openn internal overload protectio the technician should test the compressor while it is? - ANSWERcool outdoor condensing units that are installed in areas

Mostrar más Leer menos
Institución
Nate Ac Service
Grado
Nate ac service

Vista previa del contenido

nate ac service test CORRECT 100%
A technician has determined a supply in a flexible duct system is leaking. What should be checked? -
ANSWERAll connections inner and outer layers.



Electronic air cleaners can operate with internal voltages as high as? - ANSWER5000v



Why do some electromechanical type thermostats require connections to both the hot side and
common side of the low voltage transfromer - ANSWERDisplay lights must be powered using both
sides of the line



the continuity reading on a functional fuse will be - ANSWER0 ohms



a compressor with proper voltage and a hard start relayt and capacitor draws lock rotor amps on
startup. what is the problem? - ANSWER



the technician believes that a hermetic compressor has a permanently openn internal overload
protectio the technician should test the compressor while it is? - ANSWERcool



outdoor condensing units that are installed in areas where flooding is possible must - ANSWERbe
mounted above flood level



In a low voltage circuit, a corroded wire-to-terminal connection acts in the circuit like an -
ANSWERadditional resistor



a system with a reciprocating compressor is pumped down and the power is shut off. if the suction
pressure rises very rapidly this is an indication that the - ANSWER



if an air conditioning system needs to operate in a low ambient condtion, the condenser may
become to effiecent - ANSWERthe head pressure becomes too low and the condenser fan motor
needs to be slowed or stopped



to achieve a specific seer rating which components must be matched - ANSWERcondensing unit and
evaporator

, on a residental no cooling call, typically the first check would be - ANSWERif the thermostat is calling
for cooling



in an economizer system the enthalpy control is used to measure - ANSWERboth temperature and
moisture content



an air conditioner refriderant circut should be evacuated to a minimum of - ANSWER500 microns



what steps are necessary to clean a two row curved condenser coil - ANSWERseparate the two rows
of coils, spray all surfaces with proper coil cleaner and water flush



in a simple refrigeration system the refriderent boils in the - ANSWERevaporator



electronic air cleaners do not remove - ANSWERanimal fur



a delay on make relay delays load from - ANSWERfrom energizing after a fixed time after a cycle



return air leakage in a hot attic will - ANSWERdecrease capacity



When a split system air conditioner has a counterflow air handler, what are the best locations for
return air grilles? - ANSWERon a sidewall next to the ceiling



the lubricating oil primarily ised with r-22 is - ANSWERmineral oil based



other than using a two-stage compressor what is another method for capacity control -
ANSWERliquid line receiver



a system air flow check is used to diagnose - ANSWERhumidity problems



what precautions need to be taken with a packaged ac system with ductwork installed outside -
ANSWERit must be insulated and weatherproofed

Escuela, estudio y materia

Institución
Nate ac service
Grado
Nate ac service

Información del documento

Subido en
6 de noviembre de 2024
Número de páginas
8
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$13.99
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ClassRep2 Strayer University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
68
Miembro desde
3 año
Número de seguidores
46
Documentos
2177
Última venta
5 días hace

2.1

7 reseñas

5
1
4
1
3
0
2
1
1
4

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes