Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

NATE AC Service Certification Correct 100%

Puntuación
-
Vendido
-
Páginas
25
Grado
A+
Subido en
06-11-2024
Escrito en
2024/2025

A system is supplied from the factory with charge of 5 pounds 10 ounces for a 15 foot line set. The line set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added for each added foot of refrigerant line set length. What is the total refrigerant charge for the system? A. 6 ounces B. 5 pounds C. 5 pounds 10 ounces D. 6 pounds - ANSWERD. 6 pounds 15ft - 25ft = 10ft x .6 = 6 ounces 5 pounds + 10 ounces + 6 ounces 5 pounds + 16 ounces = 6 pounds The purpose of using flux when soldering is to: A. anneal the surface. B. give better heat flow. C. reduce oxidation. D. pre-seal the oxidation. - ANSWERC. reduce oxidation. Outdoor condensing units that are installed in areas where flooding is possible must: A. be mounted above flood level. B. utilize NEMA 1 enclosures. C. be mounted under an overhanging eave. D. use water resistant components. - ANSWERA. be mounted above flood level. The component used to reduce sound transmission and prevent water leaks on a rooftop air conditioner packaged unit installation is the: A. curb gasket. B. silicone caulk. C. roof flashing. D. roofing tar. - ANSWERA. curb gasket. Return air leakage in a hot attic will: A. Increase capacity B. Decrease capacity C. Increase airflow D. Decrease airflow - ANSWERB. Decrease capacity An air conditioner refrigerant circuit should be evacuated to a minimum of:

Mostrar más Leer menos
Institución
NATE AC Service
Grado
NATE AC Service

Vista previa del contenido

NATE AC Service Certification Correct
100%
A system is supplied from the factory with charge of 5 pounds 10 ounces for a 15 foot line set. The
line set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to
be added for each added foot of refrigerant line set length. What is the total refrigerant charge for
the system?



A. 6 ounces

B. 5 pounds

C. 5 pounds 10 ounces

D. 6 pounds - ANSWERD. 6 pounds



15ft - 25ft = 10ft x .6 = 6 ounces

5 pounds + 10 ounces + 6 ounces

5 pounds + 16 ounces = 6 pounds



The purpose of using flux when soldering is to:



A. anneal the surface.

B. give better heat flow.

C. reduce oxidation.

D. pre-seal the oxidation. - ANSWERC. reduce oxidation.



Outdoor condensing units that are installed in areas where flooding is possible must:



A. be mounted above flood level.

B. utilize NEMA 1 enclosures.

C. be mounted under an overhanging eave.

D. use water resistant components. - ANSWERA. be mounted above flood level.

,The component used to reduce sound transmission and prevent water leaks on a rooftop air
conditioner packaged unit installation is the:



A. curb gasket.

B. silicone caulk.

C. roof flashing.

D. roofing tar. - ANSWERA. curb gasket.



Return air leakage in a hot attic will:



A. Increase capacity

B. Decrease capacity

C. Increase airflow

D. Decrease airflow - ANSWERB. Decrease capacity



An air conditioner refrigerant circuit should be evacuated to a minimum of:



A. 0 microns.

B. 200 microns.

C. 500 microns.

D. 1200 microns. - ANSWERC. 500 microns.



Which of the following substances could create an extremely dangerous condition if used to check
refrigeration system for leaks?



A. R-22

B. Nitrogen

C. Oxygen

D. Carbon Dioxide - ANSWERD. Carbon Dioxide



The subcooling method for checking charge is generally used on air conditioners with what type of
metering?

, A. Only externally equalized thermostatic expansion valves

B. Any thermostatic expansion valve

C. Piston type

D. Any fixed metering device - ANSWERB. Any thermostatic expansion valve



Supply ducts running through unconditioned space should be insulated and have:



A. equal friction.

B. excessive air velocity.

C. a vapor barrier.

D. a transition backing. - ANSWERC. a vapor barrier.



An important consideration when installing a motorized economizer is to check to be certain that:



A. the vanes are set for a maximum 10% outdoor air.

B. the vanes open on any call for cooling.

C. the vanes operate without binding.

D. the vanes are permanently set at 50%. - ANSWERC. the vanes operate without binding.



On a 3 ton unit installation, the measure airflow equals 1550 CFM. What does this indicate?



A. Proper balancing

B. Low Airflow

C. Excess airflow

D. Improper balancing - ANSWERC. Excess airflow(400cfm per ton, 3 ton=1200cfm)



Electronic type leak detectors typically have a push-button or knob for setting a reference refrigerant
level. This feature is useful for:



A. adjusting the detector after installing a new battery.

Escuela, estudio y materia

Institución
NATE AC Service
Grado
NATE AC Service

Información del documento

Subido en
6 de noviembre de 2024
Número de páginas
25
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$14.39
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ClassRep2 Strayer University
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
68
Miembro desde
3 año
Número de seguidores
46
Documentos
2177
Última venta
5 días hace

2.1

7 reseñas

5
1
4
1
3
0
2
1
1
4

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes