Backflow Prevention Practice Exam/ Q&A/ A+ Score Solution. Terms like: Back siphonage may occur when the pressure inside copper tubing is ____? A. Greater than atmospheric pressure B. Greater than barometric pressure C. Greater than 0 gauge pressure D. Less than absolute pressure E. Less than atmospheric pressure - Answer: Less than atmospheric pressure A cross-connection may be a permanent piping arrangement or a(n) ____? A. Backflow preventer B. Church symbol C. OSHA hazardous area designation D. Railroad and highway intersection sign E. Temporary hose bibb connection - Answer: Temporary hose bibb connection The isolation of a plumbing water system hazard requires____? A. Appliance protection B. Building quarantine C. High-hazard protection D. Meter protection E. Toxin monitoring - Answer: Appliance protection A direct cross-connection suggests the piping system may be subjected to ____? A. Backpressure or back siphonage B. Back siphonage only C. Periodic inspection D. Sustained pressure E. Toxic materials - Answer: Backpressure or backsiphonage

Vista previa del contenido

Backflow Prevention Practice Exam/ Q&A/ A+
Score Solution
Back siphonage may occur when the pressure inside copper tubing is ____?
A. Greater than atmospheric pressure
B. Greater than barometric pressure
C. Greater than 0 gauge pressure
D. Less than absolute pressure
E. Less than atmospheric pressure - Answer: Less than atmospheric pressure


A cross-connection may be a permanent piping arrangement or a(n) ____?
A. Backflow preventer
B. Church symbol
C. OSHA hazardous area designation
D. Railroad and highway intersection sign
E. Temporary hose bibb connection - Answer: Temporary hose bibb connection

Page 1 of 33

,The isolation of a plumbing water system hazard requires____?
A. Appliance protection
B. Building quarantine
C. High-hazard protection
D. Meter protection
E. Toxin monitoring - Answer: Appliance protection


A direct cross-connection suggests the piping system may be subjected to ____?
A. Backpressure or backsiphonage
B. Backsiphonage only
C. Periodic inspection
D. Sustained pressure
E. Toxic materials - Answer: Backpressure or backsiphonage


A pipe restriction's flow velocity increase may allow ____?
A. Aspiration
B. Backpressure
C. Low turbulence
D. Pressure head
E. Pressure surges - Answer: Aspiration


Containing a plumbing system from the public water supply requires backflow
protection at the _______?
A. Appliance or fixture

Page 2 of 33

,B. Building foundation
C. Irrigation system
D. Service Connection
E. Sprinkler riser - Answer: Service Connection


Backflow preventer manufacturers recommend that assemblies be field-tested
annually and when_____?
A. Installed
B. Moved
C. Repaired or Installed
D. Shut down
E. Water suppliers provide notice - Answer: Repaired or Installed


A differential pressure gauge reading of 0.2 psid is represented on water column
sight tube by _____?
A. 1/16 in. (0.16 cm)
B. 1/2 in. (1.3 cm)
C. 2 in. (5.1 cm)
D. 3.5 in. (8.9 cm)
E. 5.5 in. (14 cm) - Answer: 5.5 in. (14 cm)


Pollution of a public water supply suggests the substance in the water is ____?
A. Aesthetically bad
B. Biological with virus only
C. Lowering the pH below 1.4

Page 3 of 33

, D. Radiological
E. Toxic - Answer: Aesthetically bad


Water supply contamination from backflow may result in ____?
A. A bad taste
B. Coloration
C. Death
D. Odor or smell
E. Pipe wall mineral deposit flaking - Answer: Death


To prevent backflow, an atmospheric vacuum breaker is primarily designed to
____?
A. Allow air into the outlet piping system
B. Create an elevation loop above ground
C. Introduce head loss
D. Prevent backpressure
E. Restrict velocity - Answer: Allow air into the outlet piping system


Atmospheric vacuum breakers will typically be located on ____?
A. Commercial irrigation systems
B. Fire-suppression systems
C. Plumbing fixtures or appliances
D. Utility storage tanks
E. Water service connections - Answer: Plumbing fixtures or appliances



Page 4 of 33

Información del documento

Subido en
28 de octubre de 2024
Número de páginas
33
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$23.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
docmickey
4.3
(518)
Vendido
4034
Seguidores
65
Artículos
2927
Última venta
1 mes hace

Reseñas de compradores verificados




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes