Texas Irrigation Technician Exam question and answers Backflow preventionA mechanical means to prevent a backflow A backflow deviceAny approved device that prevents an undesireable reversal of flow of water 1 column foot of water.443 psi (pretty close to 5 ft. 1 psirequires a column of water 2.31 feet tall (or 3 ft.) (or 27.75 in.) max flowrate for 1/2 in pipe (to stay below 5 fps)5 gpm max flowrate for 3/4 in pipe (to stay below 5 fps)10 gpm max flowrate for 1 in pipe (to stay below 5 fps)15 gpm max flowrate 1 1/4 in. pipe (to stay below 5 fps)25 gpm max flowrate for 1 1/2 in pipe (to stay below 5 fps)35 gpm Key requirement for RPZ backflowminimum of 12" above grade Key requirement for Double Check backflow (DCVA)If installed below grade, Test cocks must be plugged with non-ferrous (non-magnetic) material Key requirements for PVB and SVBMust be 12" above highest head, valve, pipe, fitting, or fixture Key requirements for Air GapThe recieving pipe must be 1" wider or 2 times

Vista previa del contenido

Texas Irrigation Technician Exam
question and answers
Backflow prevention✔✔A mechanical means to prevent a backflow

A backflow device✔✔Any approved device that prevents an undesireable reversal of
flow of water

1 column foot of water✔✔.443 psi (pretty close to 5 ft.

1 psi✔✔requires a column of water 2.31 feet tall (or 3 ft.) (or 27.75 in.)

max flowrate for 1/2 in pipe (to stay below 5 fps)✔✔5 gpm

max flowrate for 3/4 in pipe (to stay below 5 fps)✔✔10 gpm

max flowrate for 1 in pipe (to stay below 5 fps)✔✔15 gpm

max flowrate 1 1/4 in. pipe (to stay below 5 fps)✔✔25 gpm

max flowrate for 1 1/2 in pipe (to stay below 5 fps)✔✔35 gpm

Key requirement for RPZ backflow✔✔minimum of 12" above grade

Key requirement for Double Check backflow (DCVA)✔✔If installed below grade, Test
cocks must be plugged with non-ferrous (non-magnetic) material

Key requirements for PVB and SVB✔✔Must be 12" above highest head, valve, pipe,
fitting, or fixture

Key requirements for Air Gap✔✔The recieving pipe must be 1" wider or 2 times
bigger than the discharge pipe

zone flow✔✔how many gallons go through a zone

Backflow Prevention Assembly✔✔Any assembly used to prevent backflow into a
potable water system. The type of assembly used is based on the existing or
potential degree of health hazard and backflow condition.

booster pump✔✔increases operating pressure

Bushing✔✔The method of adapting a fitting to either a larger or smaller size.

, Check Valve✔✔A valve that allows flow in one direction but Who composes the
Irrigator Council?✔✔6 Irrigators, 3 Public members, all from the same state

What is the purpose of the Irrigator Council?✔✔Provide advice on matters
concerning irrigation

Possible consequence of installing a system w/o a license?✔✔Being charged with a
Class C misdemeanor

Absorption Rate✔✔How fast a rate at which the soil will accept water

Actual Head Pressure✔✔The operating pressure measured at the base of a
sprinkler head

How to CALCULATE Actual head pressure?✔✔subtract all pressure losses from
static pressure

air gap✔✔A complete physical separation between the free flowing discharge end of
a potable water supply pipeline and an open or non-pressure recieveing vessel

Application Rate✔✔Rate that a head applies water to the area it's spraying

What term is Application rate synonymous with?✔✔Precipitation Rate

Arc✔✔The surface area of the landscape that the head will provide water (half, full,
90, 25)

as-built plans✔✔A corrected or redrawn plan, showing location of all major
components of a system

A.W.W.A.✔✔American Water Works Association

Backflow✔✔The UNDESIREABLE reverse flow of water in a piping system

Back pressure✔✔Condition that can happen due to elevation pumps, pressure

Back siphonage✔✔backflow due to a sub atomic pressure (break in city main, fire
hydrant being used

prevents flow in the opposite direction.

Completion of irrigation system✔✔All standards are met and the irrigator is satisfied

Class Pipe✔✔Class = How many pounds of pressure it can withstand before the
pipe bursts

Información del documento

Subido en
17 de octubre de 2024
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$8.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
16
Seguidores
3
Artículos
540
Última venta
5 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes