Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 1 fuera de 2 páginas
Examen

TCEQ IRRIGATION LICENSE STUDY GUIDE 100% CORRECT!!

Document preview thumbnail
Vista previa 1 fuera de 2 páginas

BPA requirements for fertilizer injection system - ANSWERReduced Pressure Principle Assembly (RPPA) (RPZ) is required when fertilizer injection are being used. Causes backsiphonage? - ANSWERCaused by a negative or Sub-atmospheric pressure. Example-City departments are using fire hydrant or there's a city main line break, or someone sucking liquid from a glass using a straw. Causes of leaking check valve - ANSWERDebris-can enter the valve. (Can use Y strainer to provide a solution.) Definition of high-hazard system? - ANSWERNon-potable water, chemicals, fertilizers Definition of cross-connection? - ANSWERAny actual or potential connection between a potable water supply and any source of contamination or pollution. Degree of hazard - ANSWERA measure of the degree of risk or harm to the public's health. General installation requirements of BPA - ANSWERDevice must check/pass Back-siphonage, Back-pressure, constant pressure, non-health hazard, health hazard. Installation requirements of AVB - ANSWER-Installed 6" above the highest head or outlet in the system. -No Valves -Downstream. -Installed vertically. Installation and inspection requirements for public water system to BPA - ANSWER installation requirements of PVB - ANSWER12" above the highest sprinkler head Vertically installed

Vista previa del contenido

TCEQ IRRIGATION LICENSE STUDY
GUIDE 100% CORRECT!!

BPA requirements for fertilizer injection system - ANSWERReduced Pressure Principle Assembly
(RPPA) (RPZ) is required when fertilizer injection are being used.

Causes backsiphonage? - ANSWERCaused by a negative or Sub-atmospheric pressure. Example-City
departments are using fire hydrant or there's a city main line break, or someone sucking liquid from
a glass using a straw.

Causes of leaking check valve - ANSWERDebris-can enter the valve. (Can use Y strainer to provide a
solution.)

Definition of high-hazard system? - ANSWERNon-potable water, chemicals, fertilizers

Definition of cross-connection? - ANSWERAny actual or potential connection between a potable
water supply and any source of contamination or pollution.

Degree of hazard - ANSWERA measure of the degree of risk or harm to the public's health.

General installation requirements of BPA - ANSWERDevice must check/pass Back-siphonage, Back-
pressure, constant pressure, non-health hazard, health hazard.

Installation requirements of AVB - ANSWER-Installed 6" above the highest head or outlet in the
system.

-No Valves

-Downstream.

-Installed vertically.

Installation and inspection requirements for public water system to BPA - ANSWER

installation requirements of PVB - ANSWER12" above the highest sprinkler head

Vertically installed

Installation requirments of RPZ - ANSWER12" above ground

Installation requirements of DCV - ANSWERHorizontal or Vertical above or below ground.

Limits of Double check valve - ANSWERIs a high hazard/health hazard *

Limits of AVB - ANSWERCan not handle more than 12 hours of constant pressure, not approved by
the state of Texas, does not protect against back-pressure.

purpose of test cocks on DCV - ANSWERto test check valves and flush

purpose of shut off-valves on PVB - ANSWERTo test and winterize

Required back flow prevention system for booster pump - ANSWERRPZ to prevent constant back flow

Información del documento

Subido en
13 de octubre de 2024
Número de páginas
2
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
papersmaster01
3.9
(73)
Vendido
304
Seguidores
106
Artículos
14710
Última venta
2 semanas hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes