• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 34 páginas
Examen

Commercial Refrigeration Certification Exam Questions and Answers 100% Pass

Document preview thumbnail
Vista previa 4 fuera de 34 páginas

perate at high efficiency. B. ensure that frost does not accumulate. C. sub-cool the compressor. D. ensure proper oil return. - A. operate at high efficiency. The difference between the temperature of the refrigerant boiling in the evaporator and the temperature at the evaporator outlet is known as: A. evaporator superheat. B. latent heat. C. evaporator sub-cooling. D. sublimation. - A. evaporator superheat. An expansion device that is stuck open will cause: A. low suction pressure

Vista previa del contenido

©JOSHCLAY 2024/2025. YEAR PUBLISHED, 2024.
Commercial Refrigeration Certification

Exam Questions and Answers 100%

Pass


In a dry type (direct expansion) evaporator, liquid refrigerant must boil away

as close to the end of the coil as possible in order to:

A. operate at high efficiency.

B. ensure that frost does not accumulate.

C. sub-cool the compressor.

D. ensure proper oil return. - ✔✔A. operate at high efficiency.

The difference between the temperature of the refrigerant boiling in the

evaporator and the temperature at the evaporator outlet is known as:

A. evaporator superheat.

B. latent heat.

C. evaporator sub-cooling.

D. sublimation. - ✔✔A. evaporator superheat.

An expansion device that is stuck open will cause:

A. low suction pressure

,©JOSHCLAY 2024/2025. YEAR PUBLISHED, 2024.
B. a starved evaporator.

C. excessive superheat

D. a flooded evaporator - ✔✔D. a flooded evaporator

When measuring evaporator superheat on a commercial system that has a

long suction line, the pressure reading should be taken at the:

A. compressor inlet.

B. evaporator outlet.

C. condenser outlet.

D. receiver Inlet. - ✔✔A. compressor inlet. (Suction Line)

Superheat measurements are best taken:

A. during a hot pull down.

B. at 8°F to 12°F.

C. during defrost.

D. with the system operating at design conditions. - ✔✔D. with the

system operating at design conditions.

A technician is checking the superheat on a multi circuit evaporator and

finds one of the circuits has a superheat that is higher than the others. This

could be caused by:

A. a dirty coil.

B. a refrigerant overcharge

,©JOSHCLAY 2024/2025. YEAR PUBLISHED, 2024.
C. uneven air distribution.

D. a blocked distributor. - ✔✔D. a blocked distributor.

A TEV with an external equalizer is used on:

A. evaporators with a high pressure drop.

B. evaporators with a low pressure drop.

C. high temperature applications only.

D. all evaporators. - ✔✔A. evaporators with a high pressure drop.

Dry type evaporators operate most efficiently with a superheat setting of

approximately:

A. 8° F to 12°F

B. 13° F to 19°F

C. 20° F to 30°F

D. 31° F to 40° F - ✔✔A. 8° F to 12°F

An evaporator used to chill liquids in operating with a normal superheat

setting, but the system is not cooling the product properly. Which of the

following is the most likely cause?

A. overcharge of refrigerant

B. undercharge of refrigerant

C. the circulator

D. the TEV - ✔✔C. the circulator

, ©JOSHCLAY 2024/2025. YEAR PUBLISHED, 2024.
What time interval is required between each superheat adjustment?

A. Not less than 1 hour

B. About 10-15 minutes

C. At least 1/2 hour.

D. No time delay. - ✔✔B. About 10-15 minutes

A low temperature evaporator used for cooling space or product

refrigeration:

A. is the same as one used for medium or high temperatures.

B. must have fins spaced closer together.

C. must be frosted periodically.

D. must be defrosted periodically. - ✔✔D. must be defrosted periodically.

Some special applications use a flooded evaporator (operated full of

refrigerant). In order to maintain the proper level of liquid refrigerant, a ____

type metering device is used.

A. TEV

B. capillary tube

C. AEV

D. float - ✔✔D. float

A properly functioning condenser will first:

A. condense then de-superheat.

Información del documento

Subido en
10 de octubre de 2024
Número de páginas
34
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
JOSHCLAY
3.5
(93)
Vendido
429
Seguidores
16
Artículos
20785
Última venta
1 hora hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes