Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 15 páginas
Examen

MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL NEW EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS/ALREADY GRADED A+

Document preview thumbnail
Vista previa 2 fuera de 15 páginas

MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL NEW EXAM AND PRACTICE QUESTIONS EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS/ALREADY GRADED A+

Vista previa del contenido

MASSACHUSETTS OIL BURNER EXAM 2024 ACTUAL NEW EXAM AND PRACTICE QUESTIONS
EXAM COMPLETE ACCURATE EXAM QUESTIONS WITH DETAILED VERIFIED ANSWERS/ALREADY
GRADED A+
The holes that are provided in the flue pipe for combustion must be: - correct one-between the heating
unit and the draft regulator



When using a pump type smoke tester, ten full strokes are necessary to: - correct one-draw the proper
amount of flue gas past the paper



The fluid in a CO2 tester is good for about how many tests? - correct one-For about 200 tests



In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must: -
correct one-increase

Air heater - correct one-An indirect fired Appliance intended to supply heated air for space Heating and
other purposes but not intended for permanent installation



Air pressure switch - correct one-An electrical switch designed to prove that the proper draft has been
established by the power Venter or burner and allows the burner to operate. It will de-energize the
burner control circuit preventing the burner from operating, if the power venter or burner is not
performing to satisfaction.



Anti flooding device - correct one-A primary safety control that causes the flow of fuel to be shut off
upon a rise in fuel level or upon receiving excess Fuel, and which operates before the Hazardous
discharge of fuel can occur.



Low heat industrial Appliance - correct one-Appliances in which materials are heated or melted at
temperatures not exceeding 600°F (316°C) and if not larger than 100 cu ft (2.8 m3) not including any
blower equipment and blower compartment.



Medium heat industrial appliance - correct one-Appliances operating at over 50 PSIG (345 kPa) pressure
when such Appliance is larger than 100 cu ft (2.8 m3) in size. Aswell as other medium-heat appliances in
accordance with recognized good practice.

, High heat industrial Appliance - correct one-An industrial Appliance larger than 100 cu ft (2.8 m3) in size,
and other furnaces classified as high-heat appliances in accordance with recognized good practice.



Application permit/Certificate of Completion - correct one-A standard form issued for use in all
jurisdictions throughout the Commonwealth.



Approved - correct one-Unless otherwise indicated listed or approved by a nationally recognized testing
Laboratory



Authority having jurisdiction - correct one-The State Fire Marshal or his designee



Boiler - correct one-A closed vessel in which water is heated, steam is generated, steam is superheated,
or any combination thereof, by the application of heat from combustible fuels in a self-contained or
attached furnace



Boiler, High Pressure - correct one-A boiler for generating steam at pressures in excess of 15 psi (103 kPa)
or for heating water to a temperature in excess of 250° F (121°C) or at a pressure in excess of 160 PSI
(1103 kPa)



Boiler hot water supply - correct one-A low pressure hot water boiler having a volume not exceeding 120
gal (454 L) or a heat input exceeding 200,000 BTU per hour (58.6 kW) or an operating temperature
exceeding 200° F (93°C) that provides hot water to be used externally to itself



Boiler, low pressure - correct one-A boiler for generating steam at pressures not in excess of 15 PSIG (103
kPa) or for Furnishing water at a temperature not in excess of 250° F (121°C) pressure's not in excess of
160 PSIG (1103 kPa)



Burner automatically ignited - correct one-A burner equipped so that the main burner fuel may be
turned on and ignited automatically



Burner manually ignited - correct one-A burner equipped so that main burner fuel is used on only by
hand and ignited under supervision

Información del documento

Subido en
9 de octubre de 2024
Número de páginas
15
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$18.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GoldenExams
4.6
(65)
Vendido
24
Seguidores
17
Artículos
500
Última venta
18 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes