HVAC Heating test Questions With Complete Verified Solutions.

Document preview thumbnail
Vista previa 2 fuera de 7 páginas

On a central gas furnace, which of the following conditions would cause the high limit control to open circuit ? - Answer Fan contol is open After replacing the compressor in a heat pump during the heating season, a technician must charge the system to the proper lvl. Which is the most accurate method ? - Answer Weigh in the exact charge A situation in which the flame on a gas furnace continually rolls out could be caused by - Answer A plugged heater exchange On heat pumps using a liquid line temperature sensing device for the terminating defrost cycles, which causes device to terminate defrost - Answer Increase in the temperate of the liquid line In a duct system, where should vibration eliminators be placed ? - Answer Between air handler and first duct A correct statement regarding the fan/limit controller is that it senses the: - Answer Supply air temperature in the furnace A correct statement regarding suction line filter driers is that they should be used when: - Answer Replacing a compressor after a burnout The component that is installed on the low since to prevent liquid from entering the compressor is called an : - Answer Accumulator The reason many residents are not equipped to take in fresh air through duct system is because : - Answer Infiltration is used to meet the need for fresh air

Vista previa del contenido

HVAC Heating test Questions With
Complete Verified Solutions.
On a central gas furnace, which of the following conditions would cause the high limit control to open
circuit ? - Answer Fan contol is open



After replacing the compressor in a heat pump during the heating season, a technician must charge the
system to the proper lvl. Which is the most accurate method ? - Answer Weigh in the exact charge



A situation in which the flame on a gas furnace continually rolls out could be caused by - Answer A
plugged heater exchange



On heat pumps using a liquid line temperature sensing device for the terminating defrost cycles, which
causes device to terminate defrost - Answer Increase in the temperate of the liquid line



In a duct system, where should vibration eliminators be placed ? - Answer Between air handler and first
duct



A correct statement regarding the fan/limit controller is that it senses the: - Answer Supply air
temperature in the furnace



A correct statement regarding suction line filter driers is that they should be used when: - Answer
Replacing a compressor after a burnout



The component that is installed on the low since to prevent liquid from entering the compressor is called
an : - Answer Accumulator



The reason many residents are not equipped to take in fresh air through duct system is because : -
Answer Infiltration is used to meet the need for fresh air

, In a natural draft gas- fired furnace, most probable cause of the flame lifting off the burner is: - Answer
Too much gas pressure



For proper burner operation, the manifold pressure on atmospheric draft natural gas-fires furnaces
should be: - Answer 3-4 inches of water



The purpose of sequencer replays in an electric warm-air heating system is to: - Answer Prevent all
elements from being energized at same times



An increase in the latent heat load across the evaporator will cause which of the following changes: -
Answer An increase in evaporator and condenser pressure



The normal indoor airflow through a heat pump or air conditioner should be approximately - Answer
400 cfm/ton



With an oil gun burner, atomized oil is ignited by an: - Answer Electrics arc between electrodes



To check if a fixed resistance crankcase heater is operating with power applied, you would normally use -
Answer An ammeter



Which of the following is the most probable cause of a high discharge pressures in a cooling system ? -
Answer Dirty condenser coil



Commonly specified manufacturers requirements for the venting of 90+ high efficiency furnaces are
sized for vent, number of elbows, venting materials? And: - Answer Length of vent



The most important advantage of using brazing alloys with a higher silver content is that ? - Answer
The joint is stronger



On split system air conditioner, increasing the air flow through an evaporator : - Answer Will cause frost
to build up on coil

Información del documento

Subido en
8 de octubre de 2024
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
COCOSOLUTIONS
4.1
(39)
Vendido
236
Seguidores
16
Artículos
9903
Última venta
2 días hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes