G-60 - Answers-Use of oxygen and flammable gasses, or LPG or CNG for any hot work

COF exception - Answers-Torch operations for jewelry

FDNY permit - Answers-Storing using or handling

oxygen and flammable gas

in excess of 400scf (LPG, CNG or scetylene)

oxidizing gass in excess of 504scf

Portable LPG must not be stored when the capacity of the container is greater than? -
Answers-16.4 oz

Portable CNG containers must not be stored then the capacity is greater than? -
Answers-8.7 SCF

Single standard portable LPG containers must not exceed? - Answers-100LBs in weight

Single CNG containers must not exceed? - Answers-381 SCF

LPG
400 SCF is approximately - Answers-47 lbs

Types of FDNY permits - Answers-Site specific permits

City wide permits

Transportation permits

Transportation permit - Answers-FDNY approved inspected displayed on vehicle

Hot work authorization. - Answers-Required for any project with hot work operation but
not issued by the FDNY

Responsible person - Answers-Must be available for inspection by any representative of
fire department during and 48 hours after the work is complete.

Fire guard - Answers-Cof holder who is trained in and responsible for maintaijjng a fire
watch.

Fire watch - Answers-Survailance of an area
Detect signs of early fire

,Raise alarms
Notify department

Pre hot work check must be conducted by the responsible person before hot work is
authorized at least? - Answers-Once per day

Pre hot work check daily and must very the following - Answers-Equipment working in
order

Hot work is clear of combistibles and flammable solids

Combustible and non combustible are protected

Fire watch personel are assigned

Fire extinguisher available

Fire watch - Answers-A fire watch must be maintained during any hot work operation.

The person conducting a fire watch shall - Answers-Not have other duties

Fire watch

At least one portable fire extinguisher with a - Answers-Minimum 2-A:20-B:C rating shall
be accessible within 30ft from hot work

Fire watch

Exception roofing operating fire extinguisher - Answers-3-A 40-B:C

Fire watch for torch operations conducted at following locations by a F-60 fire guard: -
Answers-Construction sites

Buildings and structures

Rooftops

Site specific permit can be? - Answers-Can be permenant or temperary

Permanent permits are valid for how long? - Answers-12 months only.

Permits and renewals require inspection and will expire adter twelve months.

Temporary permits may be valid from? - Answers-One day to 12 months depending on
the construction or operations needed.

, City wise permit duration? - Answers-30 days

Hazards out end of day

Quantity of hazardous material being stored(maximum)? - Answers-5 gals gasoline
250 gals of flammable
300 gals combustible liquid

Fire watch must continue for - Answers-30 minutes after the conclusing of the work.

Time and record keeping requirements

CNG or LPG torch operations inspections - Answers-First shall be conducted 30minute
after completion

Second inspection 1 hour after completion

The inspection report must be available - Answers-48 hours after work is complete for
fire department representative to look over.

Oxygen cylinder is made of - Answers-Steel and contains 100% oxygen

Oxy propane degrees - Answers-1,500 degrees

Acetylene degrees - Answers-3000 degrees

Oxy-acetylene degrees - Answers-6000 degrees

Brazing and soldering temperatures - Answers-Typically 840 degrees

Oxy-fuel torch

Oxygen storage pressures up to - Answers-2200 PSI (pounds per square inch)

Oxy-fuel torch

Dangerous fuel gas pressures - Answers-Above 15 psi especially for acetylene

Gas torches also have applications and additions like - Answers-For burning weeds
Melting ice
Applying tar/asphalt

Backfire - Answers-Flame on torch goes out unexpectedly

A loud snap or pop may occur when the flame goes out.

Información del documento

Subido en
1 de octubre de 2024
Número de páginas
29
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GEEKA
3.8
(367)
Vendido
2177
Seguidores
1449
Artículos
61064
Última venta
6 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes