How far away must the operator stand from the xray tube if not covered with lead? -
ANSWER: 3 meters

90% of man made radiation to the population is related to? - ANSWER: Medical
Radiography and Dental

For each peak xray voltage, what lead equivalent is required?

100kV or less (o-100)
Between 101kV-149kV
150kV or greater (150+) - ANSWER: 0-100kV = 0.25mm of lead

Greater than 100kV but less then 150kV = 0.35mm of lead

150kV or greater = 0.50mm of lead

What protective equipment is required during interventional procedures - ANSWER:
Full wrap around protective gowns of 0.50mm pb in the front panels and 0.25mm pb
in the back panels

Thyroid shields with an equivalent of 0.50mm of pb

Lead drapes/curtains mounted to II of 0.25mm of pb at 100kv

What lead equivalent must protective gloves/ gauntlets possess? - ANSWER: 0.25mm
of pb

What lead equivalent must ceiling mounted lead screens and moveable shields
provide? - ANSWER: 0.50mm of pb

What are the annual radiation dose limits for radiation workers? - ANSWER: Whole
body= 20mSv
Lens of eye= 150mSv
Skin = 500mSv
Hands = 150mSv
All other organs = 500mSv

For pregnant women an effective dose of 4 mSv must be applied for the remainder
of the pregnancy from all sources

What are the annual radiation dose limits to members of the public? - ANSWER:
Whole body = 1mSv

,Lens of the eye= 15mSv
Skin = 50mSv
Hands = 50mSv
All other organs = 50mSv

*these also apply for students*

What are primary protective barriers? Give examples - ANSWER: Primary barriers
provide shielding from the direct xray beam. Such as, the walls and floor where the
tube can be directed

-The wall behind the wall bucky
-Floor under the table

What are secondary barriers and give examples - ANSWER: Provide shielding against
both leakage and scattered radiation. Walls that the primary beam is not directed
towards and the ceiling are secondary barriers.

The control booth is also a secondary barrier, the primary beam should never be
directed towards it.

What should the focal spot to skin distance be for:

-Mobile equipment
-Stationary equipment
-Radioscopic equipment - ANSWER: Must not be less than:

-Mobile: 30cm
-Stationary: 38cm
-Radioscopic: 20cm (designed for special procedures that would be impossible at
30cm or 38cm)

What are the maximum air kerma rates for radioscopic equipment:

-with automatic intensity control
-without AIC - ANSWER: Not equipped with AIC: 50mGy/min

With AIC: 100mGy/min

The air kerma rate must not exceed ___ from scattered radiation of radioscopic
equipment - ANSWER: 2 mGy/h

HVL of Aluminum for given tube voltages? (70kV-150kV) - ANSWER: 70: 2.5mm
80: 2.9mm
90: 3.2mm
100: 3.6mm
110: 3.9mm

, 120: 4.3mm
130: 4.7mm
140: 5.0mm
150: 5.4mm

How frequently should IP's and cassettes be cleaned and inspected? - ANSWER:
Cleaned: monthly
Visual inspection: Weekly

What are daily QC tests for CR/DR/Fluoro/CT equipment - ANSWER: -Warm up (all)
-Meter operation (all)
-Equipment condition (all)
-System movements (fluoro)
-Visual assessment of electronic display devices (all)

What are weekly QC tests for CR/DR/Fluoro/CT equipment - ANSWER: - Visual
inspection of cleanliness of system (all)
-Laser film printer operation (all)
-CT # accuracy
-CT noise
-CT uniformity

What are monthly QC tests for CR/DR/Fluoro/CT equipment - ANSWER: -Cassette,
screen, IP plate cleaning (CR)
-Retake analysis (CR/DR)
-Electronic display device performance (all)
-Laser film printer operation (all)
-CT slice thickness
-CT # calibration
-CT # linearity

What should the monthly retake analysis be below? - ANSWER: 5%

What are quarterly QC tests for CR/DR/Fluoro/CT - ANSWER: -Collimator operation
(CR/DR/Fluoro)
-Interlocks (all) (on doors to prevent exposure if door is open)
-Compression devices (Fluoro)
-Table angling/motion (Fluoro)
-Fluoro protection devices (lead drapes = .25mm of pb)
-CT patient support movement
-CT spatial resolution
-CT low contrast detectability

What are the annual QC tests for CR/DR/Fluoro/CT - ANSWER: -Accuracy of loading
factors (CR/DR/fluoro)
-Output reproducibility
-Output linearity

Libro relacionado
 image
Euclid Seeram Digital Radiography
Editorial: 2019 ISBN: 9789811332449 Edición: Desconocido

Información del documento

Subido en
29 de septiembre de 2024
Número de páginas
16
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
tutorsectionn
4.8
(747)
Vendido
34
Seguidores
1
Artículos
842
Última venta
7 meses hace


Reseñas de compradores verificados




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes