Journeyman Electrician Practice Test Study Guide Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - Answer️️ -THHN conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a 120/240 volt, single-phase, electrical system from the local utility company. What is the MINIMUM size aluminum THW conductors required for use as service-entrance conductors for this residence? - Answer️️ -4/0 AWG one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be sized at an ampacity of not less than 83% of the service rating. Therefore, 200 amperes x 83% = 166 amperes; size 4/0 AWG THW aluminum conductors with an allowable ampacity of 180 amperes should be selected for this dwelling. Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is installed at a multi-family dwelling, the full-load current rating, in amperes, of the secondary is _____. - Answer️️ -625 amperes TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD OWNER: EMILLYCHARLOTTE COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISHED: SEPTEMBER 2024 2/18 To find the full-load current rating of the single-phase transformer apply the single- phase current formula as shown:I = (150 kVA x 1000) / 240 volts = 15,000/240 = 625 amperes Which one of the following listed circuit breakers is NOT a standard ampere rating? - Answer️️ -75 amperes the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an ampere rating of 75 amperes is not a standard ampere rating. The MINIMUM length of free conductor to be left at each junction box for the purpose of splicing conductors, or making connections to illuminares or devices shall be _____ . - Answer️️ -6 inches free conductor is to be left at each junction box for splices or the connection of luminaires or devices. The intent of this rule is to ensure enough conductor slack for the terminal connections or splices to be made easily. In general, overhead service-drop conductors shall NOT be smaller than _____. - Answer️️ -8 AWG copper overhead service-drop conductors to be not smaller than 8 AWG copper or 6 AWG aluminum or copper-clad aluminum. Do not get service-drop conductors, the overhead TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD OWNER: EMILLYCHARLOTTE COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISHED: SEPTEMBER 2024 3/18 conductors between the utility electric supply system and the service point, confused with the service-entrance conductors, the conductors from the service point from the utility company to the service disconnecting means. When a galvanized eye-bolt is to be used as the point of attachment for an electrical service, the NEC requires the eye-bolt to be installed NOT less than _____ above finished grade. - Answer️️ -10 ft. provide adequate vertical clearance of the conductors and prevent physical damage to the conductors and prevent persons from making accidental contact with the conductors which may create a shock hazard or electrocution. In no case shall the point of attachment of the service-drop conductors to be less than 10 ft. above finished grade. Why is electrical continuity required for metallic conduit? - Answer️️ -To establish an effective ground-fault path and facilitate the operation of the over-current protective device. Electrical continuity is required for metallic conduit to establish an effective ground-fault path and facilitate the operation of the overcurrent protective device. In dwelling units, receptacle outlets installed for countertop surfaces, must be located above, but NOT more than _____ above the countertop or w

Vista previa del contenido

TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISHED: SEPTEMBER 2024

Journeyman Electrician Practice Test
Study Guide
Conductors with _____ marked on the insulation are NOT approved for use in a wet

location. - Answer✔️✔️-THHN



conductors with THHN insulation are approved for use in dry and damp locations only

and conductors with THWN, THHW, and THW insulation are recognized for use in dry

and wet locations.

Given: A one-family dwelling unit with a demand load of 200 amperes is supplied with a

120/240 volt, single-phase, electrical system from the local utility company. What is the

MINIMUM size aluminum THW conductors required for use as service-entrance

conductors for this residence? - Answer✔️✔️-4/0 AWG



one-family dwelling 120/240 volt, single-phase, service-entrance conductors to be sized

at an ampacity of not less than 83% of the service rating. Therefore, 200 amperes x

83% = 166 amperes; size 4/0 AWG THW aluminum conductors with an allowable

ampacity of 180 amperes should be selected for this dwelling.

Where a 150 kVA, single-phase transformer having a secondary voltage of 120/240 is

installed at a multi-family dwelling, the full-load current rating, in amperes, of the

secondary is _____. - Answer✔️✔️-625 amperes


1/18

,TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISHED: SEPTEMBER 2024



To find the full-load current rating of the single-phase transformer apply the single-

phase current formula as shown:I = (150 kVA x 1000) / 240 volts = 15,000/240 = 625

amperes

Which one of the following listed circuit breakers is NOT a standard ampere rating? -

Answer✔️✔️-75 amperes



the standard ampere ratings for fuses and circuit breakers. A circuit breaker with an

ampere rating of 75 amperes is not a standard ampere rating.

The MINIMUM length of free conductor to be left at each junction box for the purpose of

splicing conductors, or making connections to illuminares or devices shall be _____ . -

Answer✔️✔️-6 inches



free conductor is to be left at each junction box for splices or the connection of

luminaires or devices. The intent of this rule is to ensure enough conductor slack for the

terminal connections or splices to be made easily.

In general, overhead service-drop conductors shall NOT be smaller than _____. -

Answer✔️✔️-8 AWG copper



overhead service-drop conductors to be not smaller than 8 AWG copper or 6 AWG

aluminum or copper-clad aluminum. Do not get service-drop conductors, the overhead


2/18

, TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISHED: SEPTEMBER 2024
conductors between the utility electric supply system and the service point, confused

with the service-entrance conductors, the conductors from the service point from the

utility company to the service disconnecting means.

When a galvanized eye-bolt is to be used as the point of attachment for an electrical

service, the NEC requires the eye-bolt to be installed NOT less than _____ above

finished grade. - Answer✔️✔️-10 ft.



provide adequate vertical clearance of the conductors and prevent physical damage to

the conductors and prevent persons from making accidental contact with the conductors

which may create a shock hazard or electrocution. In no case shall the point of

attachment of the service-drop conductors to be less than 10 ft. above finished grade.

Why is electrical continuity required for metallic conduit? - Answer✔️✔️-To establish an

effective ground-fault path and facilitate the operation of the over-current protective

device.



Electrical continuity is required for metallic conduit to establish an effective ground-fault

path and facilitate the operation of the overcurrent protective device.

In dwelling units, receptacle outlets installed for countertop surfaces, must be located

above, but NOT more than _____ above the countertop or work surface. - Answer✔️✔️-

20 inches




3/18

Información del documento

Subido en
25 de septiembre de 2024
Número de páginas
18
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
EmillyCharlotte
3.6
(34)
Vendido
155
Seguidores
5
Artículos
12350
Última venta
1 semana hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes