Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 8 páginas
Examen

EPA 608 TYPE 2

Document preview thumbnail
Vista previa 2 fuera de 8 páginas

Exam study book Epa 608 Practice Tests of Karey Mattheis - ISBN: 9798727921890 (EPA 608 TYPE 2)

Vista previa del contenido

EPA 608 TYPE 2 TEST ACTUAL EXAM
Technicians maintaining, servicing, repairing or disposing of high pressure or very
high-pressure appliances, except small appliances and MVAC, must be certified
either as a Universal Technician or a ______ ___. - ANSWER: Type 2

After the installation of any type of system, the unit should be pressurized with
_____ and _____ checked. - ANSWER: nitrogen leak

Nitrogen is an ______ gas. - ANSWER: inert

In order to determine the general area of a leak, technicians should use a _____ or
_____ leak detector. - ANSWER: electronic ultrasonic

After locating the general area of a leak, ______ ______ are used to pinpoint it. -
ANSWER: soap bubbles

A refrigeration unit using an open compressor that has not been used in several
months is likely to leak from the rotating shaft ______. - ANSWER: seal

During a visual inspection of any type of system, _____ of _____ are an indicator of a
refrigerant leak. - ANSWER: traces oil

Excessive ________, caused by a low refrigerant charge, is an indication of a leak in a
high-pressure system. - ANSWER: superheat

A low ______ _______ may be the cause of excessive superheat in a high-pressure
system. - ANSWER: refrigerant charge

Epa regulations require that all comfort cooling appliances containing more than
_____ lbs. of refrigerant MUST be repaired when the annual leak rate exceeds _____
%. - ANSWER: 50 15

Epa regulations require that all commercial and industrial process refrigeration
systems containing more than _____ lbs. of refrigerant MUST be repaired when the
annual leak rate exceeds _____ %. - ANSWER: 50 35

Recovered refrigerants may contain _____, moisture, and oil. - ANSWER: acids

Recovered refrigerants may contain acids, ______, and oil. - ANSWER: moisture

Recovered refrigerants may contain acids, moisture, and ________. - ANSWER: oil

Because of the acids, moisture, and oil that may be in recovered refrigerants, it is
necessary to frequently check and change both the _____ and _____ on recycling
machines. - ANSWER: oil filter

, Recycling and Recovery machines using ______ compressors may overheat when
pulling a deep vacuum. - ANSWER: hermetic

Recycling and Recovery machines using hermetic compressors may overheat when
pulling a deep vacuum because the unit relies on the flow of ______ through the
compressor for ______. - ANSWER: refrigerant cooling

Before using a recovery unit, you should always check the _______ _______
_______, the oil level of the unit, and evacuate and recover any remaining
refrigerant in the unit's receiver. - ANSWER: service valve positions

Before using a recovery unit, you should always check the service valve positions, the
_____ _____ of the unit, and evacuate and recover an remaining refrigerant in the
unit's receiver. - ANSWER: oil level

Before using a recovery unit, you should always check the service valve positions, the
oil level of the unit and evacuate and recover an remaining refrigerant in the unit's
________. - ANSWER: receiver

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must ______ the recover/recycle equipment by recovering as
much of the first refrigerant as possible, change the filter, and evacuate. Exception:
technicians working with R - 134 A. - ANSWER: purge

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must purge the recover/recycle equipment by ______ as much
of the first refrigerant as possible, change the filter, and evacuate. Exception:
technicians working with R - 134 A. - ANSWER: recovering

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must purge the recover/recycle equipment by recovering as
much of the first refrigerant as possible, change the ______, and evacuate.
Exception: technicians working with R - 134 A. - ANSWER: filter

Technicians working with multiple refrigerants, before recovering and/or recycling a
different refrigerant, must purge the recover/recycle equipment by recovering as
much of the first refrigerant as possible, change the filter, and ______. Exception:
technicians working with R - 134 A. - ANSWER: evacuate

Recovering refrigerant in the vapor phase will minimize the ______ of oil. - ANSWER:
loss

Recovering refrigerant in the ______ phase can ______ recovery time. - ANSWER:
liquid reduce

Libro relacionado
 image
Karey Mattheis Epa 608 Practice Tests
Editorial: 2021 ISBN: 9798727921890 Edición: Desconocido

Información del documento

Subido en
25 de septiembre de 2024
Número de páginas
8
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
tutorsection1
4.9
(455)
Vendido
54
Seguidores
8
Artículos
1077
Última venta
1 semana hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes