• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 9 páginas
Examen

Lpi Level 1 Practice Test

Document preview thumbnail
Vista previa 2 fuera de 9 páginas

LPI LEVEL 1 PRACTICE TEST

Vista previa del contenido

LPI LEVEL 1 PRACTICE TEST
Which one of the following conditions will affect the rate and the extent a liquid
penetrant will enter cracks, fissures, and other small openings? - Answers -the surface
condition of the specimen being tested

Which of the following is a commonly used classification for penetrant? - Answers -post-
emulsifiable penetrant

A generally accepted method for removing excess nonwater-washable penetrant is -
Answers -wiping and cautiously cleaning the test specimen with a cleaner-dampened
cloth

All of the following parts can be tested by the liquid penetrant method except - Answers
-a part made from a porous plastic material

Which of the following discontinuities can be found by the penetrant test method? -
Answers -a surface crack

Which of the following is generally the more acceptable method for cleaning parts prior
to penetrant testing? - Answers -vapor degreasing

All of the following methods are commonly used to clean parts prior to penetrant testing
except - Answers -power wire brushing

Cutting oils may be effectively removed from parts before penetrant testing by -
Answers -vapor degreasing

The most common type of contaminant in fluorescent penetrant fluid is - Answers -water

Black light, with a proper functioning filter in place, used for fluorescent penetrant
inspection can cause permanent damage to - Answers -none of the above

All of the following basic inspection principles apply to the penetrant methods except -
Answers -indications glow when illuminated with a black light

Subsurface discontinuities can be best detected by - Answers -none of the above

Visible penetrant may be applied by - Answers -brushing, spraying, and dipping

The first step in conducting a liquid penetrant test on a surface that has been painted is
to - Answers -completely remove the paint

When using a post-emulsification penetrant, it is necessary to apply the emulsifier: -
Answers -after the dwell time has elapsed

, When conducting a water-washable liquid penetrant test, the wet developer is applied -
Answers -after the removal of the penetrant

Which of the following surface conditions could have a detrimental effect on a liquid
penetrant test? - Answers -a wet surface, a rough weld, and an oily surface

Liquid penetrant testing is capable of detecting - Answers -discontinuities open to the
surface

Black light equipment is required when penetrant testing by - Answers -the fluorescent
penetrant method

The term used to define the tendency of certain liquids to penetrate into small openings
such as cracks or fissures is - Answers -capillary action

Excess penetrant (all penetrant except that which is in discontinuities) is removed from
the specimen - Answers -after the required penetrant dwell time has elapsed

When using a post-emulsifiable penetrant, the emulsifier time should be - Answers -only
as long as necessary to remove the interfering background

when an inspector is working in a darkened area, he/she should become adjusted to the
dark before inspecting parts. The generally accepted time period for becoming
accustomed to the dark is - Answers -5 to 10 minutes

when applying penetrant by dipping, heating the penetrant prior to dipping - Answers -is
not generally recommended

A penetrant inspection cannot find - Answers -an internal cavity

All of the following materials can be tested by the usual liquid penetrant tests except -
Answers -unglazed porous ceramic

Liquid penetrant testing can be used to detect - Answers -discontinuities open to the
surface

Which of the following are commonly accepted methods for applying penetrant? -
Answers -dipping the part in penetrant (dipping), pouring the penetrant over the test
specimen (flowing), and spraying the penetrant on the test specimen (spraying)

A solvent used to clean the surface of a test specimen must possess all of the following
characteristics except that the - Answers -cleaner must not be flammable

Información del documento

Subido en
23 de septiembre de 2024
Número de páginas
9
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$11.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GEEKA
3.8
(379)
Vendido
2231
Seguidores
1451
Artículos
63163
Última venta
13 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes