SPI Practice Test Questions And Answers Graded A+. Which of the following do the source and the medium determine? a. duty factor b. frequency c. propagation speed d. axial resolution - correct answer. d. Axial resolution is affected by all of the following EXCEPT a. frequency b. damping c. spatial pulse length d. focusing - correct answer. d. Damping in a transducer a. reduces the number of cycles in a pulse and increases the quality factor b. increases the number of cycles in a pulse and increases penetration c. causes poor axial and lateral resolution d. reduces the duty factor and increases the range of transmitted frequencies - correct answer. d. Far zone beam divergence can be reduced on a single-element transducer by using a. a transducer with a smaller element diameter b. a higher frequency transducer c. a lower frequency transducer or a smaller element diameter d. adjustable focusing - correct answer. b. The area between the face of an unfocused single-element transducer and the point where the beam starts to diverge is the a. Fraunhofer zone b. refraction zone c. focal zone d. near zone - correct answer. d. Assuming a fixed frequency, what happens if the diameter of an unfocused transducer is increased? a. the far zone divergence increases b. the penetration decreases c. the length of the near zone increases d. the length of the near zone decreases - correct answer. c. Which of the following does NOT affect lateral resolution? a. focusing b. element diameter c. frequency d. bandwidth - correct answer. d. Higher frequency transducers provide a. improved lateral resolution b. smaller Doppler shifts c. improved axial resolution and reduced attenuation d. increased penetration - correct answer. a. Ultrasound waves that are traveling through a medium consist of a. electromagnetic and radio frequencies b. compressions and refractions c. electromagnetic and ionizing frequencies d. compressions and rarefactions - correct answer. d. What is the difference between audible sound and ultrasound? a. audible sound waves can travel through a vacuum b. audible sound has a higher frequency c. ultrasound has a higher frequency d. ultrasound waves are ionizing - correct answer. c. A decrease in the thickness of a piezoelectric element will result in a. a greater pulse duration b. an increase in the propagation speed c. a decrease in the quality factor if the bandwidth decreases d. an increase in the frequency of the transducer - correct answer. d.

Vista previa del contenido

SPI Practice Test Questions And Answers
Graded A+.


Which of the following do the source and the medium determine?

a. duty factor
b. frequency
c. propagation speed
d. axial resolution - correct answer. d.

Axial resolution is affected by all of the following EXCEPT

a. frequency
b. damping
c. spatial pulse length
d. focusing - correct answer. d.

Damping in a transducer

a. reduces the number of cycles in a pulse and increases the quality factor
b. increases the number of cycles in a pulse and increases penetration
c. causes poor axial and lateral resolution
d. reduces the duty factor and increases the range of transmitted frequencies - correct
answer. d.

Far zone beam divergence can be reduced on a single-element transducer by using

a. a transducer with a smaller element diameter
b. a higher frequency transducer
c. a lower frequency transducer or a smaller element diameter
d. adjustable focusing - correct answer. b.

The area between the face of an unfocused single-element transducer and the point
where the beam starts to diverge is the

a. Fraunhofer zone
b. refraction zone

,c. focal zone
d. near zone - correct answer. d.

Assuming a fixed frequency, what happens if the diameter of an unfocused transducer
is increased?

a. the far zone divergence increases
b. the penetration decreases
c. the length of the near zone increases
d. the length of the near zone decreases - correct answer. c.

Which of the following does NOT affect lateral resolution?

a. focusing
b. element diameter
c. frequency
d. bandwidth - correct answer. d.

Higher frequency transducers provide

a. improved lateral resolution
b. smaller Doppler shifts
c. improved axial resolution and reduced attenuation
d. increased penetration - correct answer. a.

Ultrasound waves that are traveling through a medium consist of

a. electromagnetic and radio frequencies
b. compressions and refractions
c. electromagnetic and ionizing frequencies
d. compressions and rarefactions - correct answer. d.

What is the difference between audible sound and ultrasound?

a. audible sound waves can travel through a vacuum
b. audible sound has a higher frequency
c. ultrasound has a higher frequency
d. ultrasound waves are ionizing - correct answer. c.

A decrease in the thickness of a piezoelectric element will result in

a. a greater pulse duration
b. an increase in the propagation speed
c. a decrease in the quality factor if the bandwidth decreases
d. an increase in the frequency of the transducer - correct answer. d.

, The resonant frequency of a pulsed-wave ultrasound transducer is dependent on

a. damping
b. the backing material
c. the thickness of the piezoelectric element and the speed of sound through the
piezoelectric element
d. the amplitude of the voltage applied to the piezoelectric element - correct answer. c.

The image is brighter at the level of the focal zone. Which of the following controls is
best to correct this?

a. overall gain
b. TGC
c. acoustic power
d. PRF - correct answer. b.

If the frequency is doubled,

a. the duty factor will increase
b. the period will double
c. the wavelength will double
d. the wavelength will be one-half - correct answer. d.

The typical range of pulse repetition frequencies in a pulse-echo ultrasound system is

a. 2,000 Hz to 20,000 Hz
b. 20 MHz to 200 MHz
c. 20,000 Hz to 200,000 Hz
d. 1,000 Hz to 2,000 Hz - correct answer. d.

If the number of cycles in a pulse is reduced,

a. the pulse repetition frequency is automatically reduced
b. the spatial pulse length increases
c. the pulse duration is reduced which results in a lower duty factor
d. the bandwidth is decreased and the quality factor is increased - correct answer. c.

The minimum reflector separation required to produce separate echoes is

a. the spatial resolution of the ultrasound system
b. the temporal resolution
c. the attenuation coefficient
d. the total attentuation - correct answer. a.

As the frequency of sound increases,

Información del documento

Subido en
21 de septiembre de 2024
Número de páginas
29
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lectsadh
3.9
(79)
Vendido
428
Seguidores
106
Artículos
13432
Última venta
17 horas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes