A capstan hoist is used on job sites for what purpose? - To raise and lower loads A company's health, safety and environment policy should be a combination of labor regulation and ? - Industry standards A gin pole, by definition, is a device unique to the telecommunication industry that allows head room above the highest fixed point on a structure to lift loads. - True A hoist operator will respond to a stop signal from whom? - Any source A hoist shall be inspected _______ before use? - Daily A hoist should be able to withstand a minimum of __________ ,the maximum intended line pull - 1.5 times A vertical lifeline shall have a minimum breaking strength of _______ lbs. - 5000 According to the applicable industry standards, what is the minimum height from a lower surface or ground where fall protection must be used? - 6 feet According to the regulations and standards, there are two levels of maximum permissible exposure. Which group is allowed at the highest level of exposure? - Industry workers All antennas are presumed active - True All cranes must be inspected _________ by a competent person before use - Daily All cranes must have a posted load chat visible from the operators station? - True All rigging equipment should be inspected daily before use - True An overhaul ball provides what function in the operations? - Provides weight allowing the load line to treturn the ground An RF monitor should be worn in areas of unknown RF exposure - True Exposure to non ionizing radiation does what to the human body? - Does not permanently change cells For all power lines rated 50kv, the minimum clearance between the lines and any part of the crane or load shall be - 20 feet For structural loading purposes the basket and bridle slings shall a

Mostrar más Leer menos
Institución
Telecom Tower Technician 1
Grado
Telecom Tower Technician 1

Vista previa del contenido

Telecom Tower Technician 1

A capstan hoist is used on job sites for what purpose? - To raise and lower loads

A company's health, safety and environment policy should be a combination of labor regulation and ? - Industry
standards

A gin pole, by definition, is a device unique to the telecommunication industry that allows head room above the
highest fixed point on a structure to lift loads. - True

A hoist operator will respond to a stop signal from whom? - Any source

A hoist shall be inspected _______ before use? - Daily

A hoist should be able to withstand a minimum of __________ ,the maximum intended line pull - 1.5 times

A vertical lifeline shall have a minimum breaking strength of _______ lbs. - 5000

According to the applicable industry standards, what is the minimum height from a lower surface or ground where fall
protection must be used? - 6 feet

According to the regulations and standards, there are two levels of maximum permissible exposure. Which group is
allowed at the highest level of exposure? - Industry workers

All antennas are presumed active - True

All cranes must be inspected _________ by a competent person before use - Daily

All cranes must have a posted load chat visible from the operators station? - True

All rigging equipment should be inspected daily before use - True

An overhaul ball provides what function in the operations? - Provides weight allowing the load line to treturn the
ground

An RF monitor should be worn in areas of unknown RF exposure - True

Exposure to non ionizing radiation does what to the human body? - Does not permanently change cells

For all power lines rated 50kv, the minimum clearance between the lines and any part of the crane or load shall be -
20 feet

For structural loading purposes the basket and bridle slings shall always be attached where? - At a panel point
around the leg

How many pounds force is one kilo Newton? - 225 lbs

How often must a fire extinguisher be inspected by a qualified person? - Annually

How often shall all gin poles have a documented job inspection? - Daily

If a synthetic rope has a breaking strength of 7600 lbs, what is the maximum gross load that can be lifted? - 760lbs

If the operator and signal person cannot see each other, what other way can they communicate? - Radios

Escuela, estudio y materia

Institución
Telecom Tower Technician 1
Grado
Telecom Tower Technician 1

Información del documento

Subido en
13 de septiembre de 2024
Número de páginas
4
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$12.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor
Seller avatar
chaserdreamer

Conoce al vendedor

Seller avatar
chaserdreamer EXAMS
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
-
Miembro desde
1 año
Número de seguidores
0
Documentos
125
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Documentos populares

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes