Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Examen

Seattle ROL Exam Study Guide with Complete Solutions

Puntuación
-
Vendido
-
Páginas
23
Grado
A+
Subido en
30-08-2024
Escrito en
2024/2025

Seattle ROL Exam Study Guide with Complete Solutions Oil pressure switch - Answer️️ -Protects the compressor from operation too long with no or partial lubrication Off cycle defrost - Answer️️ -Is used on medium temperature systems for defrost by the air in the cooler which will be above 32F. Filter - dryer filter - Answer️️ -removes dirt and moisture out of the refrigerator. Suction accumulator - Answer️️ -prevents liquid refrigerant from entering the compressor. Receiver - Answer️️ -Stores unused refrigerant that uses a metering device that varies the refrigerant flow with the load. DOT-39 Container Disposal - Answer️️ -You must evacuate it and punch a hole in a DOT-39 container before disposing of it. Two types of defrost used with low-temperature fixtures - Answer️️ -Hot Gas and Electric. By code, can a licensed Refrigeration Operating Engineer break into a Freon System in Seattle? - Answer️️ -No, they cannot break into a Freon system in the City of Seattle. ©SOPHIABENNET@ Friday, August 23, 2024 10:49 AM 2 High temperature refrigeration is between - Answer️️ -45F to 60F Medium temperature refrigeration is between - Answer️️ -30F to 45F Low temperature refrigeration is between - Answer️️ --20F to 5F The average coil to air temperature relationship of the evaporators is 15F differences leaving air and boiling refrigeration temperature. - Answer️️ - HCFC are HydroChloroFlouroCarbons and contain - Answer️️ -Contain the elements, hydrogen, chlorine, fluorine, and carbon. HFC are HydroFlouroCarbons and contain - Answer️️ -Hydrogen, fluorine, and carbons. Ozone Depletion Potential - Answer️️ -Is a measurement of CFC's and HCFC's ability to destroy the ozone. A white colored cylinder is used for - Answer️️ -R-12. A silver colored cylinder is used for - Answer️️ -R-717. On a gauge manifold the red hose is to be connected to - Answer️️ -The high side. On a gauge manifold the blue hose is to be connected to - Answer️️ -The low side. Volume of gas varies as pressure varies, but the temperature remains the same. - Answer️️ -Boyle's law ©SOPHIABENNET@ Friday, August 23, 2024 10:49 AM 3 The total pressure of a confined mixture of gases is the sum of the pressures of each of the gasses in the mixture. - Answer️️ -Dalton's law At a constant pressure, the volume of gas varies as to the absolute temperature and at a constant volume, the pressure of a gas varies directly with the absolute temperature. - Answer️️ -Charles' law A rupture disk is located - Answer️️ -On the cooler of a chiller. To test for leaks in an ammonia system - Answer️️ -You can use a sulfur candle and soap bubbles. Before you dispose of a refrigeration container - Answer️️ -You must evacuate, puncture a hole in the container; break off the valve of a refrigeration container. All refrigerant technicians must be certified after - Answer️️

Mostrar más Leer menos
Institución
Seattle
Grado
Seattle

Vista previa del contenido

©SOPHIABENNET@2024-2025 Friday, August 23, 2024 10:49 AM




Seattle ROL Exam Study Guide with
Complete Solutions

Oil pressure switch - Answer✔️✔️-Protects the compressor from operation
too long with no or partial lubrication

Off cycle defrost - Answer✔️✔️-Is used on medium temperature systems for
defrost by the air in the cooler which will be above 32F.

Filter - dryer filter - Answer✔️✔️-removes dirt and moisture out of the
refrigerator.

Suction accumulator - Answer✔️✔️-prevents liquid refrigerant from
entering the compressor.

Receiver - Answer✔️✔️-Stores unused refrigerant that uses a metering
device that varies the refrigerant flow with the load.

DOT-39 Container Disposal - Answer✔️✔️-You must evacuate it and punch
a hole in a DOT-39 container before disposing of it.

Two types of defrost used with low-temperature fixtures - Answer✔️✔️-Hot
Gas and Electric.

By code, can a licensed Refrigeration Operating Engineer break into a
Freon System in Seattle? - Answer✔️✔️-No, they cannot break into a Freon
system in the City of Seattle.




1

, ©SOPHIABENNET@2024-2025 Friday, August 23, 2024 10:49 AM




High temperature refrigeration is between - Answer✔️✔️-45F to 60F

Medium temperature refrigeration is between - Answer✔️✔️-30F to 45F

Low temperature refrigeration is between - Answer✔️✔️--20F to 5F

The average coil to air temperature relationship of the evaporators is 15F
differences leaving air and boiling refrigeration temperature. - Answer✔️✔️-

HCFC are HydroChloroFlouroCarbons and contain - Answer✔️✔️-Contain
the elements, hydrogen, chlorine, fluorine, and carbon.

HFC are HydroFlouroCarbons and contain - Answer✔️✔️-Hydrogen,
fluorine, and carbons.

Ozone Depletion Potential - Answer✔️✔️-Is a measurement of CFC's and
HCFC's ability to destroy the ozone.

A white colored cylinder is used for - Answer✔️✔️-R-12.

A silver colored cylinder is used for - Answer✔️✔️-R-717.

On a gauge manifold the red hose is to be connected to - Answer✔️✔️-The
high side.

On a gauge manifold the blue hose is to be connected to - Answer✔️✔️-The
low side.

Volume of gas varies as pressure varies, but the temperature remains the
same. - Answer✔️✔️-Boyle's law




2

, ©SOPHIABENNET@2024-2025 Friday, August 23, 2024 10:49 AM




The total pressure of a confined mixture of gases is the sum of the
pressures of each of the gasses in the mixture. - Answer✔️✔️-Dalton's law

At a constant pressure, the volume of gas varies as to the absolute
temperature and at a constant volume, the pressure of a gas varies directly
with the absolute temperature. - Answer✔️✔️-Charles' law

A rupture disk is located - Answer✔️✔️-On the cooler of a chiller.

To test for leaks in an ammonia system - Answer✔️✔️-You can use a sulfur
candle and soap bubbles.

Before you dispose of a refrigeration container - Answer✔️✔️-You must
evacuate, puncture a hole in the container; break off the valve of a
refrigeration container.

All refrigerant technicians must be certified after - Answer✔️✔️-November
14, 1994.

The make up of R-717 is - Answer✔️✔️-Ammonia.

Heat required to make a change of state is called - Answer✔️✔️-Latent heat.

Heat that can be measured by a thermostat is called - Answer✔️✔️-Sensible
heat.

The valve located at the discharge side of the receiver is called -
Answer✔️✔️-The king valve.




3

Escuela, estudio y materia

Institución
Seattle
Grado
Seattle

Información del documento

Subido en
30 de agosto de 2024
Número de páginas
23
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$10.49
Accede al documento completo:

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
SophiaBennett Howard Community College
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
141
Miembro desde
1 año
Número de seguidores
5
Documentos
9098
Última venta
3 días hace
EXAM GAME-CHANGER

Exam Questions and Answers Section : Study Like a Pro, Study Smart, Study with Sophia.

3.7

26 reseñas

5
10
4
5
3
7
2
1
1
3

Documentos populares

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes