Inspection, testing, servicing, and other maintenance of sprinkler systems must be o :## personally supervised and be performed in accordance with NFPA (National Fire Protection Association) #25 2011 edition. Automatic and non-automatic sprinkler systems shall be inspected, tested and maintained as required by NFPA #25 2011 edition by o :## competent person holding a S-12 Certificate of Fitness and employed or contracted by the owner How long must maintenance records be kept? o :## Minimum 3 years If there are 300 sprinkler heads or less how many spares must be kept on premises o :## At least 6 How often do sprinkler connections need a hydrostatic pressure test? o :## 5 years Who maintains the records of inspections, tests, servicing, and other items of maintenance? o :## Impairment coordinator Who assigns the impairment coordinator 2 | P a g e : 2 0 2 4 / 2 0 2 5 G r a d e A + Master01: DO NOT COPY AND PASTE!! August 25, 2024 Latest Update o :## Building owner Under what conditions should the fire department be notified regarding a system that is out of service? o :## - out of service on more than 1 floor of a building or - the repair cannot be completed in less than 8 hours or -there are one or more fire protection services out of order at the same time When the Cof holder observes a minor defect, he shall report the condition to the ____ ____ and if it is not corrected within ____ days it shall be deemed an ____ and reported in _____ to the ____ ____. o :## Building owner, 30, impairment, writing, FD Systems that are out of service, both planned and unplanned shall be identified by placing a tag on the following locations: o :## - FD connections - system control valves - fire command center - or clear visible location in lobby of

Vista previa del contenido

1|Page: 2024/2025 Grade A+




S12 Sprinkler Test Questions and Correct
Answers & Latest Updated
Inspection, testing, servicing, and other maintenance of sprinkler systems must be


o :## personally supervised and be performed in accordance with NFPA (National Fire
Protection Association) #25 2011 edition.



Automatic and non-automatic sprinkler systems shall be inspected, tested and maintained

as required by NFPA #25 2011 edition by


o :## competent person holding a S-12 Certificate of Fitness and employed or contracted by
the owner



How long must maintenance records be kept?


o :## Minimum 3 years



If there are 300 sprinkler heads or less how many spares must be kept on premises


o :## At least 6



How often do sprinkler connections need a hydrostatic pressure test?


o :## 5 years



Who maintains the records of inspections, tests, servicing, and other items of maintenance?


o :## Impairment coordinator



Who assigns the impairment coordinator




Master01: DO NOT COPY AND PASTE!! August 25, 2024 Latest Update

,2|Page: 2024/2025 Grade A+

o :## Building owner



Under what conditions should the fire department be notified regarding a system that is out

of service?


o :## - out of service on more than 1 floor of a building or
- the repair cannot be completed in less than 8 hours or

-there are one or more fire protection services out of order at the same time




When the Cof holder observes a minor defect, he shall report the condition to the ____

____ and if it is not corrected within ____ days it shall be deemed an ____ and reported in

_____ to the ____ ____.


o :## Building owner, 30, impairment, writing, FD



Systems that are out of service, both planned and unplanned shall be identified by placing a

tag on the following locations:


o :## - FD connections
- system control valves

- fire command center

- or clear visible location in lobby ofbuilding




Who is required to post tags at the main control valve?


o :## - master fire suppression contractor (class a or b)
-master plumber




Master01: DO NOT COPY AND PASTE!! August 25, 2024 Latest Update

, 3|Page: 2024/2025 Grade A+




What should the tags indicate?


o :## - area affected
- brief description of condition

-occupancy classification

- COF #

- est. time system will be operational




What color are tags if no impairment is found?


o :## Green



Where would a green tag be placed?


o :## Main control valve



If a system is fully out of service, what color and where should tags be placed?


o :## - white disc on all affected fire department connections
- red disc on main control valve




If a system is particularly out of service, what color and where should tags be placed?


o :## -Blue disc on all affected fire department connections
- red disc on main control valve




What should the red tag on the main control valve include?


Master01: DO NOT COPY AND PASTE!! August 25, 2024 Latest Update

Información del documento

Subido en
25 de agosto de 2024
Número de páginas
27
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Axpert
3.8
(127)
Vendido
573
Seguidores
168
Artículos
29738
Última venta
2 días hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes