Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 7 páginas
Examen

Quality Management in the Imaging Sciences 5th Edition By Jeffrey Papp 9780323261999 Chapter 1-15 Complete Guide .

Document preview thumbnail
Vista previa 2 fuera de 7 páginas

Quality Management in the Imaging Sciences 5th Edition By Jeffrey Papp 9780323261999 Chapter 1-15 Complete Guide .

Vista previa del contenido

Test Bank For Quality Management in the Imaging Sciences
5th Edition By Jeffrey Papp 9780323261999 Chapter 1-15
Complete Guide .

The greatest enemy of record image detail is:

large focal spot.
part angle.
tube angle.
motion. - ANSWER: motion.

Which device has greater sensitivity to light and provides a higher SNR (signal-to-noise ratio) and
improved contrast resolution?

A TV camera
A charge coupled device
A TV camera and a charge coupled device have equal sensitivity to light, provide equal signal-to-noise
ratio, and equal contrast resolution
None of the above - ANSWER: A charge coupled device

When using an AEC system, what will happen once the predetermined amount of radiation is
transmitted?

The x-ray exposure will continue for approximately .05 seconds
The x-ray exposure will terminate
The image receptor will be overexposed
The image receptor will be underexposed - ANSWER: The x-ray exposure will terminate

Advantages of flat-panel digital fluoroscopy system include:
1. better contrast resolution
2. uniformly distortion-free images
3. high DQE - ANSWER: 1, 2, and 3

The magnitude of the signal differences in the remnant beam that results from the differing
absorption properties of the part describes

quantum noise.
subject contrast.
image contrast.
spatial resolution. - ANSWER: subject contrast.

Which primary exposure technique factor is directly proportionate to the image receptor exposure?

kVp
mAs
SID
Tube filtration - ANSWER: mAs

PSPs must be processed and read soon after exposure because signal loss (image fading) becomes
apparent after approximately

90 minutes.
eight hours.
one week.

, three months. - ANSWER: eight hours.

Which of the following are types of beam restrictors?
I. Cones (cylinder and flare)
II. Collimators
III. Aperture diaphragms - ANSWER: All of the above

With AEC, the area of interest must be placed directly over the selected detectors in order to avoid
which two of the following? (select the two that apply)

A. Overexposure
B. Underexposure
C. Decrease in contrast
D. Increase in contrast - ANSWER: A and B

Select the one incorrect statement below:

A. A primary display workstation is one that is used for image interpretation.

B. The higher/greater the bit depth in digital imaging, the lesser the number of gray shades.

C. Exposure field recognition errors usually occur from scattered radiation outside the VOI area, often
as a result of improper alignment of part, x-ray beam, and IP.

D. Direct digital systems have a fixed spatial resolution that is determined by TFT detector element
(DEL) size. - ANSWER: B. The higher/greater the bit depth in digital imaging, the lesser the number of
gray shades.

When using an AEC system, the backup time should be set at

100% of the expected exposure time
125% of the expected exposure time
150% of the expected exposure time
175% of the expected exposure time - ANSWER: 150% of the expected exposure time

What term is used to describe the numeric value representative of the exposure the IR receives in
digital radiography?

Exposure indicator
Window level
Window width
Pixel value - ANSWER: Exposure indicator

Manipulation of grey level values is associated with

lookup table and window width
window level and lookup table.
window level and edge enhancement.
window width and edge enhancement - ANSWER: lookup table and window width

A wider (increased) window width (select the two that apply)

A. decreases the range of densities
B. increases the image contrast
C. increases the range of densities
D. decreases the image contrast - ANSWER: C and D

Libro relacionado
 image
Jeffrey Papp, PhD, RT(R) (QM) Quality Management in the Imaging Sciences
Editorial: 2014 ISBN: 9780323261999 Edición: Desconocido

Información del documento

Subido en
22 de agosto de 2024
Número de páginas
7
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$18.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
phinta004
4.7
(182)
Vendido
20
Seguidores
2
Artículos
982
Última venta
2 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes