• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 3 fuera de 29 páginas
Examen

NCCT tech in surgery practice exam

Document preview thumbnail
Vista previa 3 fuera de 29 páginas

NCCT tech in surgery practice exam 1. Laryngospasm during Induction ️ The scrubbed surgical technologist should: prepare for a tracheostomy. 2. Minimum Counts for Cesarean Section ️ The minimum number of counts for a Cesarean section case is: 4. 3. Break in Sterile Technique ️ If the surgical technologist's glove touches the outside of a package, the step to take is: the circulator removes the contaminated glove and then the technologist re-gloves herself. 4. Autoclave Log Review ️ Confirm the documentation of: exposure temperature before using the instrumentation from the autoclave. 5. Minimum Humidity in the OR Suite ️ The minimum percentage level of humidity in the OR suite is: 20%. 6. Items on Preference Card for Myelography ️ A definite item on the preference card for a myelography procedure is: contrast medium. 7. Patient Positioning for Right Total Nephrectomy ️ The patient should be positioned in the: left lateral position. 8. MH Crisis During Surgery ️ In case of a suspected MH crisis, the surgical tech should: prepare to close quickly and maintain the sterile field. 9. Addressing Hematoma Post-Mastectomy ️ If a hematoma develops and the surgeon has left the OR, the surgical technologist should: ask the surgeon to return. 10. Disinfectant for Endotracheal Tube ️ Use Cidex OPA for disinfecting an endotracheal tube used during surgery. 11. Control of Bleeding for Cervical Cone Biopsy ️ Have Monsels solution available for control of bleeding. 12. Checking ESU Generator Before Use ️ The surgical technologist should check for the: biomedical engineering sticker. 13. Emergent Gynecologic Surgery Supplies ️ For an emergent gynecologic procedure, the surgical technologist should have: Poole tip suction and Lap sponges available. 14. Blood Rinsing from Instruments ️ At the end of each case, the surgical technologist should: rinse blood from the instruments with sterile water. 15. Cardiac Arrest and CODE BLUE ️ During a cardiac arrest, the surgical technologist should: prepare internal defibrillator paddles. 16. Bowie-Dick Test Purpose ️ The Bowie-Dick test on an autoclave tests the: amount of air removed from the autoclave. 17. Intraoperative Positioning Injury Prevention ️ To prevent injury to the brachial plexus, place rolled towel padding: beneath the abducted down side arm. 18. Surgical Skin Prep for Right Arm Disarticulation ️ The correct method is to: begin at shoulder to fingertips, including flank and chest, prepping the axilla last, using as many sponges as needed. 19. Instrument for Arteriotomy Extension ️ The instrument used to extend the arteriotomy during a carotid endarterectomy is: Potts-Smith scissors. 20. Retracting Spermatic Cord During Hernia Procedure ️ Provide a moist Penrose to assist with retracting the spermatic cord. 21. Safety Strap Application in Fowler Position ️ The correct application of the safety strap is: 2 inches above the knees.

Vista previa del contenido

NCCT tech in surgery practice exam


1. Laryngospasm during Induction

✔️ The scrubbed surgical technologist should: prepare for a tracheostomy.



2. Minimum Counts for Cesarean Section

✔️ The minimum number of counts for a Cesarean section case is: 4.



3. Break in Sterile Technique

✔️ If the surgical technologist's glove touches the outside of a package, the step to take is: the
circulator removes the contaminated glove and then the technologist re-gloves herself.



4. Autoclave Log Review

✔️ Confirm the documentation of: exposure temperature before using the instrumentation from the
autoclave.



5. Minimum Humidity in the OR Suite

✔️ The minimum percentage level of humidity in the OR suite is: 20%.



6. Items on Preference Card for Myelography

✔️ A definite item on the preference card for a myelography procedure is: contrast medium.



7. Patient Positioning for Right Total Nephrectomy

✔️ The patient should be positioned in the: left lateral position.



8. MH Crisis During Surgery

✔️ In case of a suspected MH crisis, the surgical tech should: prepare to close quickly and maintain
the sterile field.

,9. Addressing Hematoma Post-Mastectomy

✔️ If a hematoma develops and the surgeon has left the OR, the surgical technologist should: ask the
surgeon to return.



10. Disinfectant for Endotracheal Tube

✔️ Use Cidex OPA for disinfecting an endotracheal tube used during surgery.



11. Control of Bleeding for Cervical Cone Biopsy

✔️ Have Monsels solution available for control of bleeding.



12. Checking ESU Generator Before Use

✔️ The surgical technologist should check for the: biomedical engineering sticker.



13. Emergent Gynecologic Surgery Supplies

✔️ For an emergent gynecologic procedure, the surgical technologist should have: Poole tip suction
and Lap sponges available.



14. Blood Rinsing from Instruments

✔️ At the end of each case, the surgical technologist should: rinse blood from the instruments with
sterile water.



15. Cardiac Arrest and CODE BLUE

✔️ During a cardiac arrest, the surgical technologist should: prepare internal defibrillator paddles.



16. Bowie-Dick Test Purpose

✔️ The Bowie-Dick test on an autoclave tests the: amount of air removed from the autoclave.



17. Intraoperative Positioning Injury Prevention

✔️ To prevent injury to the brachial plexus, place rolled towel padding: beneath the abducted down-
side arm.

, 18. Surgical Skin Prep for Right Arm Disarticulation

✔️ The correct method is to: begin at shoulder to fingertips, including flank and chest, prepping the
axilla last, using as many sponges as needed.



19. Instrument for Arteriotomy Extension

✔️ The instrument used to extend the arteriotomy during a carotid endarterectomy is: Potts-Smith
scissors.



20. Retracting Spermatic Cord During Hernia Procedure

✔️ Provide a moist Penrose to assist with retracting the spermatic cord.



21. Safety Strap Application in Fowler Position

✔️ The correct application of the safety strap is: 2 inches above the knees.



22. Cost-Saving Items for Abdominal Hysterectomy Prep

✔️ To watch costs, the surgical technologist should hold: closing suture, 11 knife blade, extra Raytec.



23. Retractors for Emergent Case on Large Patient

✔️ The surgical technologist will need a: Bookwalter retractor for an emergent case.



24. Sutures for Carotid Endarterectomy

✔️ Anticipate using 7-0 Prolene sutures.



25. Re-scrubbing After Breaking Sterility

✔️ If the surgical technologist breaks sterility, they should: prepare to scrub, re-gown, and re-glove.



26. Monitoring Fluid During Hysteroscopy

✔️ Monitor fluid intake and output to prevent swelling symptoms during a hysteroscopy.

Información del documento

Subido en
14 de agosto de 2024
Número de páginas
29
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$10.29

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
CertifiedGrades
3.9
(38)
Vendido
149
Seguidores
61
Artículos
8729
Última venta
1 mes hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes