Explain the conditions required and actions that must be attempted before a boiler start up can be attempted - ANS Make sure the boiler has a valid inspection certificate, make sure no foreign matter, such as tools or rags, is left behind, clean the boiler chemically, make sure the firing equipment is ready for startup Describe the automatic start-up sequence of a gas fired boiler fitted with a draft fan or blower. Also describe how the boiler is warmed up after starting from cold - ANS On gas-fired boilers with a standing pilot, open the pilot valve and light the the pilot. Follow the lightning instructions given on the instruction plate attached to the burner mandifold or automatic valve. When the pilot is lit and burning satisfactorily, open the stop valve in the fuel line to the main burner. It's warmed up from cold to warm slowly to prevent uneven expansion and thermal shock Describe the automatic shutdown sequence of a gas fired boiler - ANS Reset all limit switches, such as low water, which would have been tripped or opened during shut down, check the boiler control switch is in the off position List three reasons why ignition may not occur during the startup sequence of a boiler and explain each - ANS Flame scanners if they don't detect the fire in your furnace the boiler will cut off gas supply. Broken electrode will cause the pilot not to light at all. Faulty pilot ignition cable if your boiler does not seem to be attempting to ignite, check to ensure it has any power, and if not, inspect the fuse box to see if any fuse has tripped Describe two reasons why a high/ low fire burner might stay on low fire - ANS The modulating control may be malfunctioning, the igniter is defective Describe four reasons why a burner shutdown may occur during firing - ANS Too much air in the system, excessively high boiler firing rate, opening burner fuel valves before ignition is established, purging the furnace before light-off Explain step by step, the general preparations required for starting up a hot water heating boiler after a lengthy shut-down - ANS Heat up a cold boiler slowly as to avoid thermal shock and uneven expansion, because this leads to boiler leakage and costly repairs. Should any abnormal condition occur immediately shut down the boiler and close the stop valves in the fuel lines. Identify the problem before restarting the boiler. Describe how would you start up of a hot water boiler with a standing pilot - ANS First set the gas valve to the pilot. Position hold down the bypass button to let gas into pilot. Keep holding the button down and use a lighter to insert a flame over the pilot Describe two conditions that, while appearing abnormal, will disappear after a hot water heating boiler heats up - ANS 1. Slight Smoking- When a cold- fired boiler is started up, the operator may notice that during the first part of the warm-up period to the stack will smoke slightly. This is normal since the furnace temperature is not enough yet to vaporize the incoming fuel oil immediately and completely. If the stack is smoking heavily and the burner nozzle is known to be clean, adjust the air damper to obtain the proper fuel- air ratio. 2. condensation- When a cold gas fired boiler is started up, condensation will run out of the drain in the colour of the reversing chamber

Vista previa del contenido

5th Class Power Engineering Assignment
3
​




Explain the conditions required and actions that must be attempted before a boiler start up can
be attempted - ANS Make sure the boiler has a valid inspection certificate, make sure no
foreign matter, such as tools or rags, is left behind, clean the boiler chemically, make sure the
firing equipment is ready for startup

Describe the automatic start-up sequence of a gas fired boiler fitted with a draft fan or blower.
Also describe how the boiler is warmed up after starting from cold - ANS On gas-fired
boilers with a standing pilot, open the pilot valve and light the the pilot. Follow the lightning
instructions given on the instruction plate attached to the burner mandifold or automatic valve.
When the pilot is lit and burning satisfactorily, open the stop valve in the fuel line to the main
burner. It's warmed up from cold to warm slowly to prevent uneven expansion and thermal
shock

Describe the automatic shutdown sequence of a gas fired boiler - ANS Reset all limit
switches, such as low water, which would have been tripped or opened during shut down, check
the boiler control switch is in the off position

List three reasons why ignition may not occur during the startup sequence of a boiler and
explain each - ANS Flame scanners if they don't detect the fire in your furnace the boiler
will cut off gas supply. Broken electrode will cause the pilot not to light at all. Faulty pilot ignition
cable if your boiler does not seem to be attempting to ignite, check to ensure it has any power,
and if not, inspect the fuse box to see if any fuse has tripped

Describe two reasons why a high/ low fire burner might stay on low fire - ANS The
modulating control may be malfunctioning, the igniter is defective

Describe four reasons why a burner shutdown may occur during firing - ANS Too much air
in the system, excessively high boiler firing rate, opening burner fuel valves before ignition is
established, purging the furnace before light-off

Explain step by step, the general preparations required for starting up a hot water heating boiler
after a lengthy shut-down - ANS Heat up a cold boiler slowly as to avoid thermal shock
and uneven expansion, because this leads to boiler leakage and costly repairs. Should any
abnormal condition occur immediately shut down the boiler and close the stop valves in the fuel
lines. Identify the problem before restarting the boiler.

, Describe how would you start up of a hot water boiler with a standing pilot - ANS First set
the gas valve to the pilot. Position hold down the bypass button to let gas into pilot. Keep
holding the button down and use a lighter to insert a flame over the pilot

Describe two conditions that, while appearing abnormal, will disappear after a hot water heating
boiler heats up - ANS 1. Slight Smoking- When a cold- fired boiler is started up, the
operator may notice that during the first part of the warm-up period to the stack will smoke
slightly. This is normal since the furnace temperature is not enough yet to vaporize the incoming
fuel oil immediately and completely. If the stack is smoking heavily and the burner nozzle is
known to be clean, adjust the air damper to obtain the proper fuel- air ratio.
2. condensation- When a cold gas fired boiler is started up, condensation will run out of the
drain in the colour of the reversing chamber

Describe the cause of uneven expansion and what the effects of uneven expansion are - ANS
When the burner is lit in a cold fire tube boiler, the furnace and the first pass of the fire tubes will
heat up rapidly. This heat is not readily carried off by the water surrounding the tubes since
proper circulation has not been established and as a result, the metal temperature will rise
considerably. In hot water boiler with forced circulation, the metal temperature will not rise to the
same extent.

Define "thermal Shock" - ANS When metal is subjected to a sudden change in
temperature, the temperature change will not be even throughout the metal. Expansion and
contraction will not be equal in all parts of the metal. This causes strong internal stresses in the
metal, called "thermal shock"

Explain the problems which may arise by operating a gas-fired hot water heating boiler below a
temperature of 77 C (170F) - ANS Are avoided to prevent flue gas condensation

What is the recommended operating pressure of hot water heating system that has a safety
relief valve set to 827 Kpa (120 psi) - ANS The operating pressure should not exceed 620
kpa (90 psi). The reason for this recommendation is that a large pressure differential will assure
tight closing of the valve

State the advantage of having a stack thermometer - ANS To check the temperature of
the flue gases

Explain the importance of maintaining up to date records of boiler stack temperatures during
normal operations plant operation. - ANS By keeping a log of the stack temperature, a
gradual increase in temperature will tell the operator that the heating surfaces are fouling up and
that the heat transfer, and thus the boiler efficiency, is dropping. Cleaning may be required

Describe the results of excessive scale and soot in a boiler - ANS Spot deposits on the
fireside caused by improper combustion or scale and sludge deposits caused by insufficient or
improper water treatment will foul up the heating surfaces and reduce heat transfer

Información del documento

Subido en
3 de agosto de 2024
Número de páginas
15
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$9.89

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
DocLaura
4.2
(44)
Vendido
161
Seguidores
38
Artículos
6357
Última venta
1 mes hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes