Outside grease interceptors shall require a ____________. - ANS-Chamber Vent

Swimming pools: pipes that contain waste water from wading and swimming pools, back wash
filters, scum gutter drains or floor drains around walk ways around pools shall be installed
___________________ - ANS-Through Indirect waste

A gasoline trap shall be provided with a _________ type of vent. - ANS-Chamber

Cleanouts shall be required at each change in direction; greater than or including
_______________ degree fitting. - ANS-45 degrees

The stand pipe for a domestic washing machine shall extend to a minimum height of _______
above the base of the machine. - ANS-30 inches

The chamber vent for an outside grease trap shall be piped to _____________. - ANS-The
inside of the building

Grease traps shall have a grease retention capacity of not less than _______ of grease for each
G.P.M. of flow. - ANS-2 lbs.

Cleanouts shall be required at the base of vertical storm water conductors, waste, or soil _____.
- ANS-Stacks

When the seating capacity for a stadium exceeds _______ people the number of toilets shall be
calculated at the rate of 1 per. 100 women and 1 per. 200 men. - ANS-2000

Vertical cast iron soil pipe shall be supported at the base of the stack and at __________. -
ANS-Each story height

Each shower head supply riser shall be _________. - ANS-Securely Attached

Vertical PVC or ABS stainless steel tubing and aluminum shall be supported at each story
height but not more than _________ intervals. - ANS-10 ft

Cleanouts shall be required every __________ on horizontal drain pipes 4 inches of less. -
ANS-50 ft

A dormitory shall have 1 laundry utility sink for each _________ persons. - ANS-50

, Accessible cleanouts shall be installed at each change in direction of the ___________. -
ANS-Building drain

The waste from a sacrium shall not be ____________. - ANS-Trapped or Vented

Which of the following plumbing fixtures would be permitted under Mass. State plumbing code?
- ANS-Wall hung water closet

Underground cleanouts shall be extended __________ finish grade. - ANS-To or above

When a cleanout on a building drains outside of the building the cleanout shall not be more than
________ from the building wall. - ANS-5 ft

Horizontal stainless steel 1 ½ inch or more shall be supported every __________. - ANS-10 ft

The minimum size for a chamber vent for an outside grease interceptor shall not be less than -
ANS-4 inches

Floor drains and gasoline traps are required in residential garages or more than _______ cars
when living units are above or below. - ANS-6

Horizontal copper tubing 1 ½ inch or more shall be supported every __________. - ANS-10 ft

A urinal for public use shall have non-absorbent material up to _______ above the floor. -
ANS-4 ft

A drain for a Laundromat shall be of sufficient size so as to receive simultaneous discharge of
__________ of all clothes washing machines. - ANS-75%

Each building trap when installed shall have a cleanout and a _____________. - ANS-Relieving
Vent

Horizontal CPVC plastic 1 inch or less shall be supported every _________. - ANS-3 ft

The waste from a domestic clothes washing machine shall discharge through a _______ into a
laundry utility sink or stand pipe. - ANS-Air break

An indirect waste discharging into a storm drain from a swimming pool shall be connected
through a _________. - ANS-Air Gap

Horizontal PVC or ABS plastic 2 inches or more shall be supported every _________. - ANS-4 ft

A toilet seat provided for public or semi-public use shall be _________ type. - ANS-Elongated,
open front with smooth non absorbent material

Información del documento

Subido en
18 de julio de 2024
Número de páginas
7
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$8.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
scholartutor
4.8
(923)
Vendido
2789
Seguidores
3
Artículos
10768
Última venta
3 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes