• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 106 páginas
Examen

G2 Exam Prep.

Document preview thumbnail
Vista previa 4 fuera de 106 páginas

Exam of 106 pages for the course G2 Prep at G2 Prep (G2 Exam Prep.)

Vista previa del contenido

G2 Exam Prep

The best tool for adjusting and setting the pressure on an appliance regulator:

a.
Manometer

b.
Velometer

c.
Psychrometer

d.
An analyzer - ANS-Manometer

3/8 NPS black iron pipe shall?

a. Not be used for propane
b. Not be used in a concealed location
c. Not be used for natural gas
d. Not be used for indoors - ANS-Not be used in a concealed location (6.3.9)

A corrugated metal gas connector connected to a range must not exceed?

a. 6'
b. 5'
c. 3'
d. 4' - ANS-6' (6.21.3)

A manual shut-off valve shall be installed?

a. only on natural gas appliances
b. in either drop of riser of a residential appliance
c. downstream of the union
d. at the drip pocket - ANS-In either drop of riser of a residential appliance (6.18.2)

Black iron pipe 2 1/2 NPS at 150' long shall be pressure tested to?

,a. The greater of 50psig or 1.5 times the maximum operation pressure for 180 minutes
b. 50 psig for 180 minutes
c. 1.5 times the maximum operation pressure for 180 minutes
d. 50 psig for 60 minutes - ANS-50 psig for 60 minutes (Table 6.3)

Buried piping or tubing shall be?

a. only copper type L coated, type G coated, type K uncoated
b. only copper type K, L or type G
c. schedule 50 ASTM A-53
d. only copper type L or G coated - ANS-Only copper type L coated, type G coated, type
K uncoated (6.2.7)

What is pressure drop?

a. The difference in the static pressure at the meter, and the working pressure at the
appliance regulator
b. The difference between the U tube manometer is the end that is open to the
atmosphere and the pressurized side when the appliance regulator is working
c. The difference between supply pressure and appliance manifold pressure when the
appliance calls for heat
d. The difference in the working pressure at the gas meter, and the working pressure at
the appliance regulator - ANS-The difference in the working pressure at the gas meter,
and the working pressure at the appliance regulator

Fittings used for steel piping may be made from?

a. brass or iron
b. copper to malleable iron
c. steel and plastic
d. malleable iron and steel - ANS-Malleable iron and steel (6.2.2)

Posts protecting piping and tubing entering a building from vehicular damage shall be?

a. clearly marked and identified with yellow paint
b. Be spaced not more than 48" apart
c. Buried not less than 36" below grade
d. Made from 6x6 pressure treated wood - ANS-Buried not less than 36" below grade
(6.16.15)

,The equivalent length of a 2 1/2 NPS forged tee is?

a. 9.25'
b. 12.4'
c. 15.3'
d. 10.3' - ANS-9.25' (Table A 16)

What is the maximum horizontal spacing of supports for N.P.S. 1 1/4 inch gas pipe?

a. 8'
b. 15'
c. 6'
d. 10' - ANS-10' (3m) (Table 6.2)

When gas piping enters a building, it must?

a. Enter above grade
b. Be taped, painted, and sleeved
c. Have a tracer wire
d. Enter below grade - ANS-Enter above grade (6.15.8)

When sizing a branch line, what is the minimum size of job fabricated welding fittings
that can be used on a NPS 6 gas supply header?

a. 2" NPS
b. 3/4" NPS
c. 3" NPS
d. 1/2" NPS - ANS-3/4" NPS (6.8.8)

A dirt pockets shall be installed at the bottom of any piping or tubing, on the final drop
serving an appliance other than a(n)

a. Unit Heater
b. Furnace
c. Clothes dryer
d. Boiler - ANS-Clothes dryer (6.13.1)

Direct-vent wall furnace shall use what maximum length of corrugated metal gas
connector?

, a. 6 ft.
b. 4 ft.
c. 8 ft.
d. 2 ft. - ANS-2 ft. (6.21.3(c))

Every gas hose and gas fitting shall have a minimum working pressure of what.

a. 275 PSIG minimum or the setting of the hydrostatic relief valves.
b. 350 PSIG for piping and tubing operating at a container.
c. 350 PSIG
d. 250 PSIG when connected to the outlet of a pump or compressor. - ANS-350 PSIG
(6.2.9)

What are the requirements for back filling underground piping or tubing?

a. It shall not have stones larger than 38 mm
b. The fill material shall contain no sharp objects.
c. A trench must be dug 15 inches deep
d. All of the choices - ANS-The fill material shall contain no sharp objects (6.15.6)

Question 17
What is the approximate purging time for NPS 1 that is 40 feet in length?

a. 7 Seconds
b. 28 Seconds
c. 14 Seconds
d. 43 Seconds - ANS-28 seconds (Annex H Table H.1)

What is the maximum distance a readily accessible manual shut-off valve may be
installed from an appliance?

a. 2 ft. and identified
b. 10 ft. and identified
c. 25 ft. and identified
d. 50 ft. and identified - ANS-50 ft. and identified (6.18.2(d))

What is the minimum unthreaded portion of a piping outlet required when installing a
gas piping through a floor for a range?

Información del documento

Subido en
4 de julio de 2024
Número de páginas
106
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$8.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
scholartutor
4.8
(923)
Vendido
2789
Seguidores
3
Artículos
10777
Última venta
3 semanas hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes