Heat Pump Prep Test Graded A+
Heat Pump Prep Test Graded A+ An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has a ️Reversing Valve What is the difference between "demand defrost" and "timed defrost?" ️Demand defrost happens only when needed and timed defrost is based on time/temperature The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called ️outdoor ambient thermostat The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without auxiliary heat is known as ️initial balance point At what temperature is an outdoor ambient thermostat normally set ️slightly above the initial balance point the outdoor coil is frozen solid on a "no heat" service call. The most likely reason is ️the outdoor fan is inoperative in order to determine a heat pump's balance point, you must first calculate ️The building's heat load when a heat pump is used for heating and cooling, the system is sized by the ️cooling load a high efficiency heat pump system designed to function from high to low ambient conditions below 10F, may have? ️an auxiliary heat exchanger injected with an ethylene glycol solution Room thermostats for heat pump should be installed ️As near to the main return air grill as possible when the heat pump compressor has malfunctioned, the customer has the option to switch the system into ️emergency heat mode Start-up with a night set back digital thermostat requires the technician to always ️teach the customer how to program the thermostats the heat pump defrost board can be manipulated by the technician to ️simulate the defrost cycle the air-to-air heat pump outdoor unit is most efficient if located ️in a moderate climate zone which of the following are innovations that may be found on new high efficiency units? ️ECM fan motors How may a lockout (impedance) relay be reset? ️simply disconnect power to the unit momentarily the temperature difference between the 1st and 2nd bulbs for heating on a heat pump thermostats is ️approximately 2 F SEER is calculated by ️Dividing the BTUs removed by the watts consumed during the cooling season what will happen if the indoor fan is operated at an excessive speed in the cooling mode ️the system will not properly remove the humidity from the conditioned space the most preferred method of charging any system in the field is ️by weight what is the industry standard for deep vacuum? ️maintain 500 microns for 15 minutes Good service practice for installation of a reversing valve includes ️use heat paste and wet rags while brazing in the new valve off-cycle crankcase heat is provided by ️a small amount of current is passed t
Información del documento
- Subido en
- 3 de julio de 2024
- Número de páginas
- 9
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas