Cbspd exam prep Test Questions with 100% Complete Solutions, Graded A+
High-level disinfection (at least) - Semi critical devices should be processed by which disinfection method? Sterilization - Critical devices should be processed by which disinfection method? Sanitization - Non critical devices should be privy which disinfection method? Rigid, flexible, and semi-rigid - Name the three different types of endoscopic scopes: High-level disinfection - According to Spauldings classification of medical devices, a semi critical item requires which form of disinfection? As it enters the jacket - In a non-tabletop sterilizer, a gauge on the main steam line, usually located at the back of the sterilizer, tells you the steam pressure: Minimize contaminates - One reason for adding chemicals to the boiler feed water is to Chemical Monitoring - The Bowie-dick is considered which type of monitoring process? Weekly - Routine biological testing of steam sterilizers should be performed no less than Monitored with a biological indicator - All loads containing implantable devices should be Geometric center of the load - Unless otherwise directed by the sterilizer manufacturer, the ethylene oxide process challenge device (bi test pack) is placed in the: Stainless steel instruments - Which of the following is compatible with Hydrogen peroxide ozone sterilization? At least daily - Biological monitoring of the hydrogen peroxide-ozone sterilization process should be performed Cleaning - "The removal of contamination from an item to the extent necessary for further processing or for its intended use" is the Association for the Advancement of Medical Instruments definition of which of the following Air exhausted directly to the outside - Negative pressure refers to Powered Equipment - When sorting items in the decontamination area, which of the following would require manual cleaning? Immunity - The ability of the body to specifically counteract antigens refers to Measles - Which of the following is not a disease spread by droplets? Vectors - Lyme disease is generally transmitted by defense mechanisms - The sterile processing technician does not have an impact on which of the following elements of the chain of infection? Time immersed, time taken out, temperature of the solution and initials of the technician who handled the instrument - When taking an instrument out of a HLD, what should be notated on the record log? At least 1 in - How many inches of space should there be between the chamber walls and packages to prevent scorching of package materials? 90% - What is a log reduction of 1? 68-73 degrees/ 50%-35% - The temperature/ humidity range in prep and pack should be: 3 to 3 1/2 minutes @ 270 or 273 with no drying time. - What is the cycle for specified for a Bowie-Dick test? Involves the use of external chemical indicators to verify that a load has been subjected to a sterilization process; the use of internal indicators to verify that individual packages have been exposed to necessary conditions for sterilization. - Chemical monitoring: Verified that the sterilization conditions within the load were adequate to kill a known number of bacterial spores. - Biological monitoring Biological monitoring - - is the only way to measure the lethality of a sterilization process. Geobacillus stearothermophilus - The spore that is most resistant to steam sterilization is Indicator tape - Type 1 process indicators
Información del documento
- Subido en
- 8 de mayo de 2024
- Número de páginas
- 14
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas