• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 14 páginas
Examen

MECP Practice Test Correctly Solved

Document preview thumbnail
Vista previa 2 fuera de 14 páginas

How much power is a source unit that puts out 6 volts per channel into 4 ohms? - 9 volts per channel The measurement of the voice coil of a speaker with a DMM set to ohms while at rest is which of the following? - DC Resistance A security system is being blamed for draining the battery on a vehicle overnight. A series parasitic current drain test is performed with a DMM. Technician A says if the current drain is 150ma or below, it's fine and not indicative of the security system causing the issue. Technician B says to compare the current draw initially measured with a second measurement of the security system disconnected from power. Whose statements are correct? - Neither Technician A nor Technician B correct. An RTA is connected to the speaker outputs of the OEM amplifier. A pink noise signal is played in the factory system and the output from the OEM amplifier is shown on the RTA. Technician A says this signal is a 20-20khz full range signal. Technician B says this a low passed signal that shows it connects to the factory subwoofer. Who is correct? - Neither Technician A nor Technician B is the correct. To measure the signal level of an analog audio signal, a DMM must have a measurement scale that displays which one of the following units? - AC Volts What is the name of signal that electrically reports engine speed? - Tachometer Signal In a positive switching, high current ignition system, which of the following ignition switch circuits has +12v in the RUN and START positions, but not during ACC. - Ignition #1 (primary or “True" Ignition) In a positive switching, high current ignition system, which of the following ignition switch circuits has +12 in the ACC and RUN positions, but not during START? - Ignition #2 (secondary Ignition) After a remote starter is manually shut down and the security system is armed, the Rap feature keeps the radio on and needs to be shut down electronically. The door switch circuit is normally open, positive trigger. Two technicians suggest a wiring an SPDT relay to solve the RAP shutdown, each of which is wired differently from the other. Based on the diagrams (A= Technician A, B= Technician B), who is correct? - Only Technician B


Información del documento

Subido en
30 de abril de 2024
Número de páginas
14
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$10.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
kharowl
3.0
(2)
Vendido
14
Seguidores
7
Artículos
1498
Última venta
10 meses hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.