CDFA Weight Verification Practice Questions with Complete Solutions
CDFA Weight Verification Practice Questions with Complete Solutions Specifications are particularly directed to Manufacturers of devices Newly manufactured scales are required to be designated as Class I, II, III, IIIL, or IIII The normal valance position of the weighbeam of a beam scale shall be horizontal A county sealer/ director of W&M may, with the approval of the Secretary of Food and Agriculture, use a frequency of inspection which is Different from regulations On a prescription scale equipped with a balance indicator, if this indicator consists of an indicator and a graduated scale and they are not in the same plane, the clearance between the indicator and the graduations shall not be more than 0.04 inches Graduations of a scale beam shall be so varied in length that they may be conveniently read A poise stop is not necessary on a steelyard when there is no zero graduation The adjusting material in a poise shall be securely enclosed and firmly fixed in position and it shall not be in contact with the weigh beam, if softer than brass The sensitivity requirement of a scale shall be applied in conjunction with regardless of maintenance and acceptance tolerances A variable frequency inspection plan shall provide for testing of all commercial devices on regular frequency, variable frequency and statistical sampling procedure Each weighing device shall have a minimum of one permanent and conspicuous identification marking with what information Name, initials or trademark of the manufacturer or distributor, model number, and non repetitive serial number The graduated interval is distance from the center of one graduation to the center of the next graduation in a graduated series non retroactive means Only enforceable with respect to devices made after implimentation Meat beams, steelyards, portable platform, and belt conveyor scales all have a frequency of inspection which is identical An axle load scale is normally permanently installed what term does not apply to nose iron range The term nominal when used in reference to a scale, measure, weight, etc. means intended or stated value A tare mechanism is used primarily for the purpose of balancing out the weight of empty containers the director may issue rules and regulations for device repairmen, accuracy of commercial devices, and responsibilities of device repairmen To perform a shift test on a dairy product test scale the necessary test weight load is 18 grams A weighing device found correct by a repairman authorized pursuant to law may be used commercially pending re-inspection by a sealer Correct means any weight, weighing, or counting instrument which Meets all tolerance and specification requirements established by regulations of the director A scale with an indicator and graduations
Información del documento
- Subido en
- 26 de abril de 2024
- Número de páginas
- 19
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas