Fire Inspector II Test Where would you look to determine if the damper requirements have been included and correct on a set of drawings? - On the mechanical plan Which plans sheet gives specific details for exit signs? - Electrical plans Which plan would you look at to find exit door fire ratings? - Door schedule All of the following items can be verified on the life safety floor plan Except - The location of fire hydrant connections Which view should inspectors examine to see a horizontal cross section of the complete building from exterior wall to exterior wall and from the foundation to roof - Sectional view To validate the dimensions on set of construction drawings, you must check the - Scale Air conditioning systems should be equipped with dampers to? - Close off sections of the ductwork if a fire is detected Inspection requirements for HVAC systems are found in NFPA - 90A Following installation, all vents are subject to an inspection and? - An acceptances performance test Air conditioning systems present unique hazards that include all of the following except - Flooding According to the national institute of standards and Technology (NIST), a non combustible powerhouse has fire load categorized as - Slight Fire load in a building is given in - Pounds per square foot or Newton's Gas cabinets and exhausted enclosures are often used to - Increase the threshold for areas containing compressed gases In which standard would you find the MAXIMUM allowable qualities of a compressed gas for specific control area - NFPA 55 Identify the two types of ventilation requirements for all tanks storing flammable and combustible liquids - Normal / Emergency Storage tanks containing class 1 class 2 class 3A liquids cannot have supports made of - Pressure treated wood Emergency drain systems for flammable or combustible liquids the connect to public waterways must be equipped with a trap for - Separator The flammable limits for hazardous chemical can be found - On the MSDS The common identification system implemented in an area where the materials are regularly stored and used is the - NFPA 704 system Which of the following is an example of an explosive - Small arms ammunition Any material or make sure that contains a fuel and an oxidizer is - A blasting agent Requirements for grease removal device is associated with cooking equipment can be found in - NFPA 96 Spray area ducks should be made out of - Steel The greatest amount of flammable and combustible liquids a flammable liquid storage cabinet in a dipping and coding area is permitted to hold is - 120 gallons Dipping in coding areas must be separated from other operations materials or occupancy by firewalls or - Fire partitions Let's go Wayne requirements for spray areas are specified in - NFPA 33 When used in reference to fire extinguishers, the term "travel distance " means - The walking distance from any hazard to the nearest fire shank sure meaning the hazard requirements Mounting height requirements for fire extinguishers are based on the fire extinguishers wait. A fire extinguisher that weighs more than 40 pounds must be installed to the top of the fires measure is not more than - 3-1/2

Mostrar más Leer menos
Institución
Fire Inspector II
Grado
Fire Inspector II










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Fire Inspector II
Grado
Fire Inspector II

Información del documento

Subido en
11 de abril de 2024
Número de páginas
18
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ExcellentScores Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
295
Miembro desde
3 año
Número de seguidores
227
Documentos
4200
Última venta
1 mes hace
WisdomWeave: Your Gateway to Intellectual Exploration

At WisdomWeave, I'm excited to be your guide in the world of intellectual exploration. Here, I've gathered documents that act as keys, unlocking doors to knowledge and understanding. Join me in this adventure, where each document is a step toward a richer, more informed mind. Let's embark on a journey together, exploring ideas and expanding our intellectual horizons.

3.9

74 reseñas

5
42
4
7
3
9
2
4
1
12

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes