Fire Inspector II Test
Fire Inspector II Test Where would you look to determine if the damper requirements have been included and correct on a set of drawings? - On the mechanical plan Which plans sheet gives specific details for exit signs? - Electrical plans Which plan would you look at to find exit door fire ratings? - Door schedule All of the following items can be verified on the life safety floor plan Except - The location of fire hydrant connections Which view should inspectors examine to see a horizontal cross section of the complete building from exterior wall to exterior wall and from the foundation to roof - Sectional view To validate the dimensions on set of construction drawings, you must check the - Scale Air conditioning systems should be equipped with dampers to? - Close off sections of the ductwork if a fire is detected Inspection requirements for HVAC systems are found in NFPA - 90A Following installation, all vents are subject to an inspection and? - An acceptances performance test Air conditioning systems present unique hazards that include all of the following except - Flooding According to the national institute of standards and Technology (NIST), a non combustible powerhouse has fire load categorized as - Slight Fire load in a building is given in - Pounds per square foot or Newton's Gas cabinets and exhausted enclosures are often used to - Increase the threshold for areas containing compressed gases In which standard would you find the MAXIMUM allowable qualities of a compressed gas for specific control area - NFPA 55 Identify the two types of ventilation requirements for all tanks storing flammable and combustible liquids - Normal / Emergency Storage tanks containing class 1 class 2 class 3A liquids cannot have supports made of - Pressure treated wood Emergency drain systems for flammable or combustible liquids the connect to public waterways must be equipped with a trap for - Separator The flammable limits for hazardous chemical can be found - On the MSDS The common identification system implemented in an area where the materials are regularly stored and used is the - NFPA 704 system Which of the following is an example of an explosive - Small arms ammunition Any material or make sure that contains a fuel and an oxidizer is - A blasting agent Requirements for grease removal device is associated with cooking equipment can be found in - NFPA 96 Spray area ducks should be made out of - Steel The greatest amount of flammable and combustible liquids a flammable liquid storage cabinet in a dipping and coding area is permitted to hold is - 120 gallons Dipping in coding areas must be separated from other operations materials or occupancy by firewalls or - Fire partitions Let's go Wayne requirements for spray areas are specified in - NFPA 33 When used in reference to fire extinguishers, the term "travel distance " means - The walking distance from any hazard to the nearest fire shank sure meaning the hazard requirements Mounting height requirements for fire extinguishers are based on the fire extinguishers wait. A fire extinguisher that weighs more than 40 pounds must be installed to the top of the fires measure is not more than - 3-1/2
Escuela, estudio y materia
- Institución
- Fire Inspector II
- Grado
- Fire Inspector II
Información del documento
- Subido en
- 11 de abril de 2024
- Número de páginas
- 18
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
fire inspector ii test
Documento también disponible en un lote