Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 5 páginas
Examen

RCDD TEST QUESTIONS (TOPIC 22 - TOPIC 24) VERIFIED 100% CORRECT!!

Document preview thumbnail
Vista previa 2 fuera de 5 páginas

RCDD TEST QUESTIONS (TOPIC 22 - TOPIC 24) VERIFIED 100% CORRECT!! Which of the following is an alarm management output system? A. Patient monitoring system B. Bed monitoring system C. Security system D. Wireless telephone system D. Wireless telephone system The ________ system is an application used for storing and viewing captured digital radiology image files. A. CCU B. ICU C. DICOM D. PACS D. PACS Which of the following is used to create an electronic signal that can be sent to the central nurse call equipment? A. Headend module B. Initiation device C. Notification device D. Two tone device B. Initiation device You are designing an interactive patient television system (IPTS) that will provide internet, nurse call and LCD television services. From the following, which medium will NOT support these services in a backbone cabling system? A. Balanced twisted pair B. Coaxial 1/2 inch hard-line cable C. Multimode optical fiber cable D. RG-11 coaxial cable A. Balanced twisted pair How much area of wall space is needed in the telecommunications room (TR) to support a nurse call system? A. 1.2m x 1.2 m (4 ft x 4 ft) B. 1.2m x 2.4 m (4 ft x 8 ft) C. 2.4 m x 2.4 m (8 ft x 8 ft) D. 2.4 m x 3.6 m (8 ft x 12 ft) B. 1.2m x 2.4 m (4 ft x 8 ft) You are designing a nurse call system for a health care facility. The system will have emergency call switches. What is the first step you should take in designing the nurse call system? A. Properly size the supporting TR to accommodate the headend system B. Program the headend device for the various call switches that will be used C. Perform a risk assessment to determine call switch locations D. Perform a site survey to verify the pathways that will connect the headend device with the call switches C. Perform a risk assessment to determine call switch locations You are renovating telecommunication rooms that support an acute care facility that has10,000 sq ft floors. The facility will be adding 15,000 sq ft to each of the floors. What is theMINIMUM additional floor space that you will need to expand the TRs to support the new floor space? A. 3 m x 3 m (10 ft x 10 ft) B. 3.5 m x 4.3 m (11.5 ft x 14 ft) C. 3.0 m x 4.5 m (10 ft x 15 ft) D. 6 m x 6 m (20 ft x 20 ft) B. 3.5 m x 4.3 m (11.5 ft x 14 ft) You are designing a nurse call system for an assisted care facility. What type of nurse call system would best suit the needs for the facility? A. Audiovisual system - B. Staff emergency system - C. Tone/Visual system - D. Bedside system - C. Tone/Visual system - Coupling with electrical circuits can create inductive interference to telecommunications facilities. Which of the following can decrease the coupling effect? A. Decrease the exposure length B. Make sure that the single-phase components add in phase C. Decrease the physical separation D. Increase the earth resistance A. Decrease the exposure length What is the air change requirement for a tunnel of 610 m (2000 ft) long with a diameter of3.4 m (11 ft)? A. One complete air change per hour B. Two complete air changes per hour C. Three complete air changes per hour D. Four complete air changes per hour E. Five complete air changes per hour C. Three complete air changes per hour A telephone facility and an electrical facility are required in a tunnel. To reduce the effects of EMI and eliminate the need for additional shielding of the cables,


Información del documento

Subido en
9 de abril de 2024
Número de páginas
5
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$11.50

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
ACADEMICSTORE
5.0
(3)
Vendido
25
Seguidores
14
Artículos
1293
Última venta
1 año hace


Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.