2011 update DC Third testing verified solutions
2011 update DC Third testing verified solutions The component in which liquid vapor by absorbing heat is called? Evaporator Select the best answer electrical grounding method? Metal stake drive 8 foot into the ground. A _____ valve should be used for throttling purpose? Globe What is the acceptable range for residual sodium sulfite in the boiler maintain? 30-70 What is the BTU content of a gallon of #4? 146,000 What does a zeolite water softener system use as a means of regeneration? Brine What are the 4 steps for a Zeolite Rejuvenation water softener process? Back wash Backwash, brine, rinse, service Where is medium temperature is liquid found? Condenser Where is high temperature vapor found? At the discharge of the compressor or condenser What stays are used to support the burner chamber in a scotch marine boiler? Diagonal Stays What type of safety valve is this? ( Full) Crosby nozzle-type safety valve. Page 365 BOG What type of safety valve is this? ( Full) Crosby nozzle-type safety valve. Page 365 BOG Where do you found superheat reading? Take suction line pressure Cross reference using a P/T Chart Get tail coil Temperature Subtract cross references temperature from tail coil temperature Result will be superheat Name the wire that connects all component of a system to a physical ground or water pipe? Grounding Electrode Conductor Where do get sub-cooling reading? Take liquid line pressure Cross reference to temperature using a P/T Chart Get liquid line temperature Subtract actual temperature from cross referenced temperature Result is sub-cooling On the boilers that have both Quick opening and Screw type blow down valves, the Quick opening valve must be located? Closest to the boiler and followed by the screw type valve High pressure boilers equipped with Quick opening and Screw type valves are blown down how? By opening the Quick opening valve first and closing it Last. Page 403 BOG ASME Code defines a slow opening valve as what? One requiring at least 5 full 360 degree turns between full open and close position. Page 374 A 300 Horsepower boiler operating at 100psi has an average load of 75% with 80% condensate return and 5% blow down. The treatment provides a chemical which costs $8.75 per gallon, and will treat 600 gallon. Find the amount of the chemical needed for the day period, and the cost of the chemical for a 30 days period? Water In = Water Out Makeup + Condensate Return = Evaporator + Blow Down Average Evaporator Rate = 300 x 34.5 pph x .75% load = 7762, 50 pph
Información del documento
- Subido en
- 23 de marzo de 2024
- Número de páginas
- 27
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas