P98 Questions & Answers Updated
P98 Questions & Answers Updated Fuel-oil is generally used in buildings in stationary equipment for two purposes - Answersfuel emergency generators or to fuel equipment used to heat the building. the person supervising the Fuel-Oil Transfer in the Building from one floor to another must hold - AnswersP-98 Certificate of Fitness. Certificate of Fitness holders must maintain all qualifications and comply with all requirements applicable to such certificate holders throughout the term of their certificate. The P-98 Certificate of Fitness is premise-related. The use of the word "should" throughout these study materials generally refers to - Answerspolicies, procedures and/or best practices recommended by the FDNY, and may not be a codified requirement. The use of the word "shall" throughout these study materials generally refers - Answersto a requirement of the Fire Code or the FDNY. 3.1 SUPERVISION OF FUEL-OIL PIPING AND STORAGE OPERATIO - Answers A stationary fuel-oil storage tank, and related piping, that is installed on the lowest floor of a building and that transfers fuel-oil through piping to another stationary fuel-oil storage tank, or to fuel-oil burning equipment, installed above such floor, shall be under the - Answersthe GENERAL SUPERVISION of a P-98 Certificate of Fitness holder The periodic inspection and testing of such tanks and piping shall be conducted under the - AnswersPERSONAL SUPERVISION of such P-98 Certificate of Fitness holder. Fuel-oil storage tanks and piping systems shall be inspected at least once ----for any evidence of leaks - AnswersWeekly Fuel-oil storage tanks subject to this section shall have their float switches tested at least once ---- to ensure that they are in good working order. - AnswersWeekly Who is required for all existing and new buildings where fuel is being transported from the lowest levels to tanks or equipment on upper floors pursuant to the new NYC Fire Code and Mechanical Codes? - AnswersThe COF holder The oil storage tank - Answersprovides the supply of oil for combustion in the oil burner The oil storage tank is inside a ---- - Answersdike In case of a leak the ---- area will contain the oil - Answersdiked In its normal condition, #2 oil fuel is - Answersthin and light and is easily pumped through the circulation system. A suction pump does what? - Answerscirculates the oil throughout the system. What are present in the fuel-oil coming from the oil storage tank? - AnswersDirt and sediment The ---- removes most of these contaminants from the oil before the oil reaches the burner's strainer. - Answersoil filter The suction line has to be ---- inches from the bottom of the tank for sediments not to be absorbed - Answers6 The vacuum gauge - Answersa device that measures pressure below atmospheric pressure. Excessive vacuum readings (in the vacuum gauge) indicate that - Answersthere is an obstruction in the suction line (such as dirty oil strainer). When the vacuum gauge shows obstruction in the suction line it can be stopped by closing the - Answersshut off valve Closing the shut off valve - Answerspermits the operator to clean the filter/strainer or to perform other maintenance. The main fuel valve is - Answerselectrically operated and will open or close the line leading to the atomizer only for oil burners. It will shut down the burner system if there is a failure of ignition or combustion. The oil return line - AnswersOil circulates through the piping system back to the storage tank through it (the oil return line) A ---- is provided for safety if the pressure becomes too great. - Answersback pressure relief valve
Información del documento
- Subido en
- 7 de marzo de 2024
- Número de páginas
- 21
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas