MN Boilers test practice (special) The dial on a steam gauge on a low-pressure boiler must be graduated from _ to _ times the maximum allowable working pressure - correct answer 1 1/2 to 2 What is the minimum size of pipe diameter that may be used to attach a steam gauge to a steam boiler? - correct answer 1/4 inch Steam boilers are designed to operate at or below what PSI? - correct answer 15 Liquid Boilers are designed to operate at or below what PSI? - correct answer 160 What is the term of the area of the boiler that has water/liquid on one side and the heat source on the other? - correct answer Heating Surface What type of safety valve is required on a steam boiler? - correct answer Spring-Loaded When the heating surface of a _____-pressure boiler exceeds ____ square feet, the minimum number of safety valves is what? - correct answer High, 500, 2 or more 4 1/2 inches is the maximum size safety valve that may be installed on on a _________ boiler - correct answer low-pressure The maximum size safety relief valve on a low-pressure boiler is what? - correct answer 4 1/2 inches How many Kw equals 1 boiler horsepower? - correct answer 10 10 Kw is equal to how much boiler horesepower? - correct answer 1

Vista previa del contenido

MN Boilers test practice (special)

The dial on a steam gauge on a low-pressure boiler must be graduated from _ to _ times the maximum
allowable working pressure - correct answer 1 1/2 to 2



What is the minimum size of pipe diameter that may be used to attach a steam gauge to a steam boiler?
- correct answer 1/4 inch



Steam boilers are designed to operate at or below what PSI? - correct answer 15



Liquid Boilers are designed to operate at or below what PSI? - correct answer 160



What is the term of the area of the boiler that has water/liquid on one side and the heat source on the
other? - correct answer Heating Surface



What type of safety valve is required on a steam boiler? - correct answer Spring-Loaded



When the heating surface of a _____-pressure boiler exceeds ____ square feet, the minimum number of
safety valves is what? - correct answer High, 500, 2 or more



4 1/2 inches is the maximum size safety valve that may be installed on on a _________ boiler - correct
answer low-pressure



The maximum size safety relief valve on a low-pressure boiler is what? - correct answer 4 1/2 inches



How many Kw equals 1 boiler horsepower? - correct answer 10



10 Kw is equal to how much boiler horesepower? - correct answer 1

, What does ASME stand for? - correct answer American Society of Mechanical Engineers



What does NBIC stand for? - correct answer National Board Inspection Code



What kind of stamp is needed in order to legally be able to weld on a boiler? - correct answer "R"



In the state of Minnesota, how often do Boilers get inspected by an insurance company or a State Boiler
Inspector? - correct answer Yearly



How many square feet is considered equivalent to 1 boiler horsepower? - correct answer 10



What must be easily accessible/in view in the boiler room? - correct answer Boiler log, certificates of all
employees qualified to work on boiler



What is the minimum size pipe that may be used to connect a water column to high pressure boilers?
(other than miniature boilers) - correct answer 1 inch



Water columns of steel must be used if pressure is over _____ psi - correct answer 350



An outside _____ and ______ _______ valve may be used between a high-pressure steam boiler and the
water column - correct answer screw, yolk, gate



How must water column connections be at right angle turns to enable cleaning and inspections? -
correct answer Must be a cross instead of an elbow.



_____ is the minimum size drain required on a water column - correct answer 3/4 inch



If the water gauge glass became plugged or broken on a steam boiler, the boiler could temporarily
operate using the _____? - correct answer gauge-cocks(try-cocks)



A ______ cock used on a steam gauge must be a _ or ____ valve - correct answer Stop, T, lever

Información del documento

Subido en
11 de febrero de 2024
Número de páginas
7
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$22.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Studyclass
3.4
(11)
Vendido
28
Seguidores
12
Artículos
4570
Última venta
7 meses hace


Reseñas de compradores verificados




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes