CPR questions with solutions 2024
To avoid fatigue, when should team roles alternate providing compressions? every 5 cycles or 2 minutes Which team role keeps track of interruptions in compressions? timer/recorder Which team role makes treatment decisions and assigns roles? team leader Which of the following are resuscitation triangle roles in a high-performance team? -AED/Monitor/Defibrillator -compressor -airway While performing high-quality CPR, when do pauses in compressions typically occur? -intubation -compressor switches -defibrillation -rhythm analysis -pulse checks Assesses the patient and provides compressions compressor Operates the AED and alternates with the Compressor after every 5 cycles or 2 minutes to avoid fatigue monitor/defibrillator provides ventilation airway Assigning your team members to individual roles and outlining what each member needs to do during the resuscitation attempt is an example of what element of high-performance team dynamics? clear roles and responsibilities You and your team have initiated compressions and ventilation. The AED was attached, and "no shock" was advised. Your team has continued CPR for 1 minute. You tell your team in a respectful, clear, and calm voice, "Leslie, during the next analysis by the AED, I want you and Justin to switch positions, and I want you to perform compressions for the next cycle." Leslie replies, "Got it. Next time the AED analyzes, I will switch with Justin and assume the role of Compressor." This is an example of which element of high-performance team dynamics? closed-loop communication As Team Leader, you notice that your Compressor is pushing too fast. It is important to correct actions that are incorrect, but it is also important to be tactful when delivering this correction to a colleague. This is an example of what element of team dynamics? constructive intervention What action can you take as a team during and after a resuscitation attempt that helps individual team members perform better and brings awareness to system strengths and deficiencies? debriefing AED special considerations hairy chest, water, transdermal medicine patch, implanted defibrillator or pacemaker, defibrillation for infants less than 1 year of age Hairy chest -if your AED has 1 set of pads and a razor, quickly shave the area and then apply the pads -if your AED has 2 sets of pads, use the first set to remove the hair. Apply the first set of pads, press them down so they stick as much as possible, and quickly pull them off. Then apply the new, second set of pads Water -if someone is lying in water, quickly move the victim to a dry area; if the victim is lying is snow or a small puddle, use the AED -if the chest is covered with water or sweat, wipe the chest before attaching the pads Transdermal medicine patch -do not place the pad directly over a medicine patch -take the patch off and quickly wipe the chest before you put on the pad Implanted defibrillator or pacemaker -if you see a lump indicating a device, avoid placing the pad directly over it Defibrillation for infants less than 1 year of age -a manual defibrillator is preferred rather than an AED -if a manual defibrillator is not available, an AED with a pediatric does attenuator is preferred -if neither is available, you may use an AED without a pediatric dose attenuator What are examples of effective team dynamics? clear roles and responsibilities
Escuela, estudio y materia
- Institución
- Cpr cert
- Grado
- Cpr cert
Información del documento
- Subido en
- 25 de enero de 2024
- Número de páginas
- 9
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas
Temas
-
cpr to know
-
aedmonitordefibrillator