Anesthesia Technologist Review 1 questions and answers correctly solved.
Anesthesia Technologist Review 1 questions and answers correctly solved. An air buble of significant size is trapped in an arterial blood gas syringe that is not rmoved prior to analytical sampling. The air bubble will decrease: - correct answers.PaCO2 An air bubble of significant size is trapped in a mixed venous blood sample that is not removed prior to analytical sampling. The trapped air bubble will increase: - correct answers.Pvo2 An arterial blood gas sample is drawn on a patient in the operating room on the third floor and needs to be sent for analysis to the central lab that is on the ninth floor. To prepare the sample, the anesthesia tech must: - correct answers.Label the syringe with the correct patient indentification and place on ice. When preparing to draw a point-of-care sample for analysis in the OR, the technician preparing the sample must: - correct answers.The technician should use the appropriate PPE to floolw standard precautions. Aseptic technique is then followed when drawing the sample. The agency responsible for safety of medical gas cylinders is: - correct answers.FDA, DOT, OSHA, NFPA, and CGA This law refers that with gases pressure and volume are related - correct answers.Boyle's Law A liquid is defined as that temperature at which the vapor pressure equals atmospheric pressure is the definition for - correct answers.Boiling Point The measure of the volatility of the liquid anesthetic in the carrier gas is the definition for: - correct answers.Vapor Pressure ASTM mandates the vapor output cannot increase by more than____with flush - correct answers.10% This may be decreased by reducing the circuits's length, increasing diameter, and maximizing laminar flow - correct answers.Breathing system resistance Which of the following agents may use a variable bypass vaporizer for delivery? - correct answers.Halothane, enflurane, isoflurane, and sevoflurane *****not Desflurane**** The severity of an electrical shock is detemined by - correct amount of current and the duration of flow The line isolation monitor is a device: - correct answers.That continuously monitors the integrity of the isolated power system When using a electrosurgical unit, the unit cannot be safely used unless: - correct answers.The energy is routed from the unit through the patient and back to the unit via a dispersive pad. Desiccated carbon dioxide absorbents in the presence of this volatile anesthetic may result in a fire: - correct answers.Sevoflurane-The interaction of desiccated Baralyme® with sevoflurane can produce absorbent temperatures of several hundred degrees centigrade. The increase in temperature may cause anesthetic circuit fires and patient injury If a fire occurs the first step that should be taken is to remove one component of the fire triangle. - correct answers.True-Disconnecting and removing the source of oxygen is usually the quickest way to get the fire under control Allogeneic Blood is: - correct answers.Blood that is donated by one individual to be transfused to another. Autologous Blood is: - correct answers.The patients own blood. Three different types of Autotransfusion include: - correct answers.Introperative Salvage, predonation, and acute normovolemic hemodilution One benefit of the use of autotransfusion is that the patients gets their own blood back, thereby reducing reactions to the transfusion and reduces the possibility of giving the patient the wrong blood. - correct answers.True The association responsible for publishing guidelines for the use of autotransfusion is: - correct answers.AABB An indication for the use of autotransfusion is: - correct answers.When the anticipated blood loss is 20%
Información del documento
- Subido en
- 15 de enero de 2024
- Número de páginas
- 10
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas