Fire Inspector I David Jackson Questions with 100% Correct Solutions
An example of a fire hazard is: A. The absence of a reuired sprikler system B. A frayed or damaged electrical extension cord with exposed wiring placed under a rug C. A malfunctioning fire extinguisher - B. A frayed or damaged electrical extension cord with exposed wiring placed under a rug Which statment describes Department of Defense Instruction 6055.06? A. It supersedes other safety programs B. It establishes the foundation for fire inspection and education programs C. It requires welding certification - B. It establishes the foundation for fire inspection and education programs A family housing briefing should include a: A. Discussion of escape plans from the home B. Review of all applicable codes and standards C. Housing representatives - A. Discussion of escape plans from the home The best way to organize your time each day is will: A. A brisk walk B. Three 15-minute breaks C. A daily planner - C. A daily planner The reference library provides the authority and guidance for the inspection, maintenance, and testing for all of the following EXCEPT: A. portable fire extinguisher criteria B. Standards for facilities C. Installed systems criteria D. Pumper apparatus criteria - D. pumper apparatus criteria Today you are conducting an inspection of the base education center. Upon arriving at the center, you explain that the primary goal of the inspection is to: A. Ensure the safety of the occupants B. Locate unauthorized self-help projects C. Check for faulty wiring - A. Ensure the safety of the occupants The service-specific item that contains a checklist of area/systems to inspect is: A. A self-help authorization form B. UFC C. The Life Safety Code handbook D. the fire prevention protection record - D. The fire prevention Protection Record A violation that is identified and corrected during an inspection is written up in the inspection record/report as: A. A "potential" fire safety deficiency B. corrected on the spot C. A potential fire hazard - B. Corrected on the spot One difference between a dry pipe system and a wet pipe system is that: A. A dry pipe system can never be used to distribute water, while a wet pipe system can ONLY be used to distribute water B. Water in a dry pipe system is held back by air pressure, while a wet pipe system has water throughout. C. A dry pipe system is always larger in diameter than a wet pipe system - B. Water in a dry pipe system is held back by air pressure, while a wet pipe system has water throughout. The extinguishing agent most effective on a fire involving animal or vegetable oils is: A. dry chemical B. halon C. wet chemical D. water - C. Wet chemical CO2's main utility as an extinguishing agent is its: A. Smothering capacity B. cooling effect C. ability to be used around people - A. Smothering capactiy A central station fire alarm system: A. is located in the center of a large buisness park B. does not involve local alarm systems C. Ties several remote local alarm systems into a central location - C. Ties several remote local alarm systems into a central location The kind of smoke detector that uses a pump to draw air samples into a high-humidity chamber is a: A. cloud chamber air sampling detector B. pipe systems air sampling detector C. Fixed temperature detector - A. cloud chamber air sampling detector A building with a large glass atrium would best be served by using a: A. light-scattering smoke detector B. Rate compensation detector C. Light obscuration smoke detector - B. Rate compensation detector Use a portable fire extinguisher with a rating of 4-A, 20-B:C on: A. ordinary combustibles, flammable liquids, and energized electrical equipment B. Extra hazard areas only B. Combustible metal fires only - A. ordinary combustibles, flammable liquids, and energized electrical equipment The NFPA manual that covers the use, installation, and maintenance of fire extinguishers is: A. NFPA 60 B. NFPA 10 C. NFPA 1 D. NFPA 15 - NFPA 10 A building is being constructed in the Petroleum Oil Liquid (POL) storage area. The class of roof covering that should be used for protection against this severe hazard is: A. Class A B. Class B C. Class C D. Class D - A. Class A Doors and windows allowed in a fire wall are referred to as: A. Resistant openings B. Rated openings C. Protected openings - C. Protected openings According to the LIFE SAFETY CODE, a facility that is used to teach 7th grade math classes to groups of 25 students is classified as: A. An assembly occupancy B. An educational occupancy C. A business occupancy - B. An educational occupancy The gross floor area of a building that is 40 feet long by 25 feet wide is: A. 1000 square feet B. 500 square feet C. 1000 square meters - A. 1000 square feet
Información del documento
- Subido en
- 11 de octubre de 2023
- Número de páginas
- 20
- Escrito en
- 2023/2024
- Tipo
- Examen
- Contiene
- Preguntas y respuestas