• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 1 fuera de 4 páginas
Examen

EPA Study test with Complete Solution 2023

Document preview thumbnail
Vista previa 1 fuera de 4 páginas

EPA Study test with Complete Solution 2023 1992--Residential Lead-based Paint Hazard Reduction Act of 1992, provides a comprehensive national approach to dealing with LBP in the nation's housing stock - Title X conditions causing exposure to lead from dust, soil, or paint that is deteriorated or present in accessible, friction, or impact surfaces that would result in adverse health effects that comes from; dust, soil, paint that is deteriorated or present on accessible, friction, or impact surfaces - LBP hazards (Title X) surface dust in residences that contain an area or mass concentration of lead above levels determined to pose a health threat to pregnant women or young children - Lead-contaminated dust (Title X) bare soil on residential property containing lead above levels determined to be hazardous to human health by the appropriate federal agency - Lead-contaminated (Title X) Disclosure of Information Concerning Lead Upon Transfer of Residential Property required HUD and EPA to create a rule regarding target housing - Title X Section 1018 1) purchasers/lessees receive EPA's lead pamphlet 2) sellers/lessors disclose all known lead hazards to purchasers/lessees 3) purchasers have a 10-day period for inspection for LBP hazards 4) sales contracts contain a Lead Warning Statement - What are the requirements for the Title X Section 1018? any housing constructed prior to 1978 EXCEPT for: 1) housing for the elderly or persons with disabilities UNLESS any child who is less than 6 years of age resides or is expected to reside in such housing 2) any 0-bedroom dwelling - What is target housing considered for Title X section 1018? National Lead Laboratory Accreditation Program - What does NLLAP stand for? Lead-Based Paint Poisoning Prevention Act - What is the LBPPPA? to reduce levels of paint in federally financed and subsidized housing and to fund screening and research programs amended in 1973--require HUD to take steps to eliminate as much as possible hazards of lead-based paint poisoning in federally financed and subsidized housing - What is the purpose for the LBPPPA? any paint, varnish, stain, or other applied coating that has 1 mg/cm^2 (or 5,000 ug/g by dry weight) or more of lead - What do the HUD guidelines define LBP as? 30 ug/m^3 of air (8-hour average) - What is the action level for OSHA? 50 ug/m^3 of air (8-hour average) - What is the permissible exposure limit for OSHA? up to 50 ug/dL whole blood - What is the allowable blood lead level for OSHA? 3 tests averaging 50 ug/dL blood or 2 tests (periodic and follow-up of 6 ug/dL) - What is the medical removal criteria for the general industry standard regarding OSHA? 2 tests (periodic and follow-up) 50 ug/dL of lead in blood - What is the medical removal criteria for the construction interim final rule regarding OSHA? semi-annual exposure monitoring at a minimum-more frequently when workplace changes may affect exposure levels. - What are the requirements for any occupational exposures at or above the action level? the testing must be offered at no cost to the employee and at a reasonable time and place. blood-lead testing frequency depends upon exposure levels and blood-lead levels but is required before job assignment to use as base-line - What happens with the medical surveillance program if exposure is at or above AL for 30 days/year (doesn't have to be consecutive)? 1) exposure monitoring (quarterly)--additional monitoring if changes may affect exposure level 2) engineering and work practice controls 3) written compliance program (prior to beginning the job) 4) protective clothing 5) hygiene facilities 6) respiratory protection program 7) warning signs - What are the requirements for any occupational exposure above the permissible exposure limit (without regard to repoirators)?


Información del documento

Subido en
31 de agosto de 2023
Número de páginas
4
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$8.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Academicmines
4.0
(18)
Vendido
96
Seguidores
55
Artículos
2686
Última venta
3 semanas hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.