• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 11 páginas
Examen

HVAC EPA 608 Certification Study Guide With Complete Solution

Document preview thumbnail
Vista previa 2 fuera de 11 páginas

Are there drop-in replacements for R-12 systems? Why or why not? - Answer No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. What type of oil is used in R-134a and what oils will it mix with? - Answer Ester based oils and they do not mix with other oils What type of lubricant is used with HCFCs? - Answer Alkylbenzene lubricant What is difference b/w ternary blend a azeotropic blend? - Answer Ternary blends are three-part mixtures whereas azeotropic blends are blends of two or more compounds that act like a single compound. What is the trait of a hygroscopic lubricant? - Answer It absorbs (takes on) moisture What is temperature glide and what type of blend won't have it? - Answer Temp. blend is the difference between the dew point and the bubble point Dew Point - Answer Occurs when saturation temp in evaporator causes refrigerant to change from liquid to vapor Bubble Point - Answer Occurs when saturation temp in condenser changes refrigerant from vapor to liquid Will the gases in a ternary blend leak at the same rate? Why or why not? - Answer No because different refrigerants in blend have different vapor pressures, causing them to leak at uneven rates Refrigeration Process - Answer transfer of heat from one place to another Evaporator - Answer Absorbs heat into system from space to be cooled. Absorption of heat causes refrigerant to boil. Upon leaving, refrigerant changed to low pressure, low temperature vapor Compressor - Answer Takes low pressure, low temp vapor and changes it to a high-temp, high-pressure, superheated vapor and delivers it to the condenser Condenser - Answer Rejects heat from system and changes refrigerant from high-temp, high-pressure vapor into high-pressure, high-temp liquid Metering Device - Answer reduces pressure of refrigerant and changes the high-pressure, high-temp liquid into low pressure, low temp liquid. Compound Gauge - Answer Typically blue and measures low pressure (psig) and vacuum (inHg). High Pressure Gauge - Answer Red and measures high side (discharge) pressure. 0 to 500 psi What does a compressor compress? - Answer Vapor Why will refrigerant migrate to the crankcase in a compressor? - Answer Because of the vapor pressure difference between refrigerant and oil What color is the high pressure gauge? - Answer Red What color is the low pressure gauge? - Answer Blue What needs to happen if oil has been contaminated by burnout? - Answer Triple evacuate system, install permanent filter-drier, conduct deep vacuum before recharging What are three Rs of refrigeration? - Answer Recover, recycle, reclaim Recover - Answer to remove any refrigerant in any condition from system and store in external container without necessarily testing or processing in any way Recycle - Answer To clean refrigerant for immediate reuse by separating oil from refrigerant and removing moisture and acidity from refrigerant by use of products like filter driers Reclaim - Answer To process refrigerant to level of new product specifications as determines by chemical analysis What standards must refrigerant recovery equipment meet and what components must all Type I and Type II refrigerant systems have? - Answer EPA-approved equipment testing organization. Service aperture or process stub System-Dependent Devices - Answer Capture refrigerant with assistance of compressor and/or pressure of refrigerant in appliances from which refrigerant is being recovered Self-contained Devices - Answer Have independent means to draw refrigerant out of appliances What is nitrogen and a filter-drier used for after recovery? - Answer Use nitrogen to flush debris out of system after recovering refrigerant. Filter-drier should be installed to trap any debris that may cause damage to new compressor What must be done before starting an evacuation? - Answer Recover all refrigerant and attain the mandated vacuum level ASHRAE Standard 15-1994 - Answer Requires refrigerant sensor that will sound alarm and automatically start ventilation system in occupied equipment rooms where refrigerant from leak will concentrate


Información del documento

Subido en
23 de agosto de 2023
Número de páginas
11
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas
$12.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Grademasters
3.8
(46)
Vendido
118
Seguidores
69
Artículos
2591
Última venta
1 mes hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.