Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 3 fuera de 26 páginas
Examen

ICA SCHOOL TEST|UPDATED&VERIFIED|GUARANTEED SUCCESS

Document preview thumbnail
Vista previa 3 fuera de 26 páginas

CCST is: Continuous Structural Steel Tubing Copper Shielded Steel Tubing Corrugated Stainless Steel Tubing Corrugated Shielded Structural Tubing - correct answer Corrugated Stainless Steel Tubing The Standards of Practice for home inspections: Defines optional services that home inspectors may provide. Provides a business model for starting a home inspection company. Defines the curriculum for a home inspection training program. Defines what is and what is not included in a standard home inspection. - correct answer Defines what is and what is not included in a standard home inspection The inspector is NOT required to: Operate all plumbing fixtures. Observe functional flow. Describe water heating equipment. Operate main shut-off valves. - correct answer Operate main shut-off valves What is flashing? Material that covers exposed edges of roofing where it meets chimneys or sidewalls to prevent water intrusion. Flames jumping back and forth from the burners into the combustion area of a furnace. The material used to hold bricks together. Wiring that has been subject to excessive heat. - correct answer Material that covers exposed edges of roofing where it meets chimneys or sidewalls to prevent water intrusion What deficiency would cause the replacement of a forced-air gas furnace? Leak in the flue pipe. Crack in the heat exchange.r Failure to the blower motor. Banging noise in the duct work. - correct answer Crack in the heat exchanger Blisters and bubbles on a built-up roof usually indicate: That there is moisture trapped between the felt-plies. That the gravel needs to be replaced. Lack of proper ventilation in the attic. Chimney flashing problems. - correct answer That there is moisture trapped between the felt-piles The standards of practice: Help to limit the liability of a home inspector. Should always be followed to the letter. Refer to all properties and property types. Are revised according to the needs of the client. - correct answer Help to limit the liability of a home inspector What is the minimum clearance from combustibles for a single wall furnace vent? 18" 9" 6" 8" - correct answer 6" A gas dryer can: Vent into a chimney. Share a bathroom exterior exhaust vent. Vent to the exterior. Merge with water heater flue vent. - correct answer Vent to the exterior In a solid brick house, what is a sign of corner settlement? step cracks at an exterior corner going down to the top of the foundation. a pair of angled cracks above the corner window. deteriorating mortar at the corner. spalling on the bricks at the corner. - correct answer Step cracks at an exterior corner going down to the top of the foundation It is preferable to put wood shingles and shakes over what type of roof sheathing to allow them to dry quickly? Plywood. Oriented Strand Board. 1 X 10 boards. Spaced or "skip" sheathing. - correct answer Spaced or "skip" sheathing Vapor barrier should be: To the cold side. To the warm side. To either side. Depends on where installed. - correct answer To the warm side The three main components of an air conditioning system are: The fan, the coil, and blower. Duct work, the expansion valve, and the coil. Evaporator coil, condenser, and compressor. Compressor, refrigerant, and blower. - correct answer Evaporator coil, condenser, and compressor What is a functional flow test? Operating the furnace and the water heater simultaneously. Running multiple plumbing fixtures in the house simultaneously. Operating the sump pump and the ejector pump simultaneously. Running plumbing fixtures in the same bathroom simultaneously. - correct answer Running plumbing fixtures in the same bathroom simultaneously Differential cracking in a residential foundation is usually: Typical. Caused by improper gutters. An indication of a structural problem. Just a condition that


Información del documento

Subido en
1 de julio de 2023
Número de páginas
26
Escrito en
2022/2023
Tipo
Examen
Contiene
Preguntas y respuestas
$17.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
GUARANTEEDSUCCESS
4.4
(251)
Vendido
686
Seguidores
314
Artículos
24885
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.