CBSPD: Chapter 10: Sterilization Exam Solved 100% Correct
The process by which all forms of microbial life are destroyed is - ANSWER-Sterilzation The sterilizer's heat-sensing thermometer is located in the: - ANSWER-Drain line In non-tabletop steam sterilizers, where are PCDs placed to present the greatest challenge? - ANSWER-Over drain The 3 parameters for steam sterilization are - ANSWER-Steam pressure, time, temperature Which of the following is the minimum exposure time for wrapped goods in a prevac steam cycle at 275 deg F? - ANSWER-3 min IUSS is appropriate when - ANSWER-One of a kind instrument is dropped For sterilization to occur, steam must: - ANSWER-Make direct contact with all surfaces Which step should be taken when a wet pack is noticed while unloading the sterilizer? - ANSWER-Reprocess the item Which method of sterilization is used to sterilize liquids? - ANSWER-Gravity steam For sterilization, paper-plastic peel packages should be placed: - ANSWER-On their edge In a mixed load of textile and metal goods, the textile packs should be placed - ANSWER-On top rack Stacking of rigid sterilization containers on the autoclave rack is permitted when: - ANSWER-The manufacturer provides technical data stating that is is acceptable What is used to verify that the sterilizer air removal mechanism is functioning properly? - ANSWER-Bowie-Dick test Which of the following monitor methods verifies that conditions Within the load were adequate to kill bacterial spores? - ANSWER-Biological What is the correct action to take if a written item needs to be removed from the load record? - ANSWER-Draw a line through the item and initial A type 5 indicator is called a - ANSWER-Integrator The Bowie dick test is used to monitor - ANSWER-Dynamic-air-removal cycles What should be done if the Bowie dick tests fails the first time? - ANSWER-Report to supervisor Which is right setting for Bowie dick? - ANSWER-3 1/2 to 4 minutes at 270 DART If a biological test is performed daily, how often is it necessary to incubate a control biological indicator? - ANSWER-Once a day, and if a new lot number is used In event of positive BI, how many loads should be called back? - ANSWER-All loads back to last negative BI Routine BI testing for steam sterilizers should be performed AT LEAST: - ANSWER-weekly All loads containing implantable devices should be: - ANSWER-Monitored with a BI When cooled items are unloaded from the steam sterilizer rack, they should be handled with: - ANSWER-clean hands What is the maximum number of 100% EO cartridges stored outside its container? - ANSWER-12 The basic parameters of gas sterilization in a 100% EO sterilizer are concentration, exposure time, : - ANSWER-Humidity and temperature Which of the following is critical to EO Penetration of bacterial cells? - ANSWER-humidity Generally, the EO biological test pack is placed in the: - ANSWER-Geometric center of the load The parameters for low temp gas plasma sterilization are - ANSWER-Time, temp, hydrogen peroxide Which of the following microorganisms is used to biologically monitor the dry heat sterilizer? - ANSWER-Bacillus atrophaeus Which of the following microorganisms is used to biologically monitor the low temp gas plasma sterilizer? - ANSWER-Geobacillus Stearothermophilus items to be sterilized in low temp gas plasma must be packaged in - ANSWER-non cellulose based material; tyvek
Información del documento
- Subido en
- 6 de abril de 2023
- Número de páginas
- 3
- Escrito en
- 2022/2023
- Tipo
- Examen
- Contiene
- Preguntas y respuestas