• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 2 fuera de 5 páginas
Examen

Kettering Study Guide RPSGT Review Section B

Document preview thumbnail
Vista previa 2 fuera de 5 páginas

Kettering Study Guide RPSGT Review Section BEEG, EOG, EMG, and ECG minimum sampling rate 200 samples per second (Hertz) Maximum sampling rate for EEG, EOG, EMG, and ECG 500 samples per second (Hertz) Thermocouple/Thermistor Responds to temperature change, detects the rate of temperature change between expired air and room air known as the Seebeck effect. Detects airflow at the nostrils and mouth. Respiratory inductive plethysmograph (RIP belts) Uses a piezo-electric sensor, one belt goes around the upper abdomen just above the belly button and one belt goes around the chest. Considered the gold standard. Piezo belts Contain a piezo crystal device that is located on a very small portion of the belt. Ineffective if the patient were to lie on the sensor. Ineffective if the belts become loose. Mercury strain gauges Contains a tube with mercury. Not used often because of possible breakage and leaking of the mercury. Intercostal EMG Least expensive, rarely used during PSG, Likely to contain ECG artifact. Esophageal pressure (Pes) Invasive, Esophageal manometry, esophageal catheters, esophageal balloons, water filled catheters. Rarely used in routine PSG and very uncomfortable. Very accurate method of measuring intrathoracic breathing effort. Measures upper airway resistance. Cardio-pneumographs Heart rate and respirations on one channel. Batter is required. Pulse oximetry Most appropriate noninvasive technique for continuous monitoring of oxygen saturation (SPo2) and pulse. Normal Spo2 on room air is 95%-97%. Spo2 decreases with respiratory events. Troubleshooting pulse oximetry Motion artifact (most common problem), dark skin pigmentation, nail polish, ambient light, may need to be re-attached if it falls off or malfunctions. Nasal pressure transducer Detects fluctuations in pressure from inspiration and expiration. Measure airflow through a nasal cannula. Very accurate in detecting hypopneas and RERA's. Best used with a DC amplification system. Capnography/End tidal C02 (ECO2, EtCO2, PetCO2) monitoring A graphic display of CO2 levels as they change. Measures exhaled carbon dioxide content using infrared absorption. What conditions affect the ventilation/perfusion (V/Q) ratio of the lungs that can alter the ETCO2? COPD, when CPAP or BIPAP is applied, sleep may alter the differences between PaCO2 and PetCO2, Obesity hypoventilation. Transcutaneous PO2 and PCO2 monitoring (PtcO2/PtcCO2) Commonly used in neonatal and pediatric sleep studies. Placement of the electrode is best over flat areas with good perfusion such as the chest just beneath the center of the right or left clavicle. Snore mic sensors (larygngeal microphones) Record vibrations to send to the amplifier. Avoid placing over the carotid artery. CPAP goals Maintain a patent airway, decrease the work of breathing, improve ventilation/perfusion ratio, improve oxygenation. continuous positive airway pressure (CPAP) Most common therapy for obstructive sleep apnea. Filters room air and delivers it to the patient via tubing and a nasal mask or full face mask. Pressure is measured in centimeters of water pressure.


Información del documento

Subido en
11 de diciembre de 2022
Número de páginas
5
Escrito en
2022/2023
Tipo
Examen
Contiene
Preguntas y respuestas
$9.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
maxiscore
4.0
(40)
Vendido
162
Seguidores
123
Artículos
7032
Última venta
2 meses hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes

Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.