Question:
1. Windows

Answer:
Windows are not exits.


Question:
2. Doors

Answer:
Normally they should be kept closed to limit the spread of smoke.


Question:
3. Exits separation in unsprinklered buildings

Answer:
If the diagonal measurement of a space is 200', exits must be separated by at least 100'.


Question:
4. Egress capacity of a door

Answer:
To calculate the egress capacity of a door, the factor to use is 0.2" per occupant.


Question:
5. Occupant load

Answer:
The occupant load determines the number of people who might occupy a given area.


Question:
6. Standard occupant load factors

Answer:
In order to calculate the occupant load for a building, the fire inspector needs Standard
occupant load factors from NFPA 1.


Question:
7. AHJ increase occupant load

,Answer:
The AHJ can increase the designed occupant load when other parts of the means of egress are
sufficient.


Question:
8. Exit access

Answer:
The exit access is that portion of a means of egress that leads to the entrance of an exit.


Question:
9. Exit discharge

Answer:
That portion of a means of egress between the termination of the exit and a public way is the
exit discharge.


Question:
10. Exits must be

Answer:
Exits must be remote from each other.


Question:
11. Free and unobstructed exit access

Answer:
If the exit access passes through an area containing a fire hazard, the principle of free and
unobstructed exit access is violated.


Question:
12. Minimum exits for occupancy load

Answer:
The minimum of 4 exits are necessary for an occupancy load of 1000 or more.


Question:
13. Egress capacity in multistory buildings

Answer:
In multistory buildings, the floor requiring the greatest egress capacity dictates the minimum
stair width from that floor down to the exit discharge.


Question:
14. Occupant load for stairs

, Answer:
In a 5-story building, if all but the 3rd floor have a capacity of 100 and the 3rd floor has a
capacity of 200, the correct occupant load for the stairs below that level must be calculated.


Question:
15. Width of any component of the means of egress

Answer:
Usually not less than 36".


Question:
16. Maximum projection at each side of a means of egress

Answer:
4½", provided they do not occur above 38" from the ground.


Question:
17. Required means of egress from any area

Answer:
2, as specified by the Life Safety Code.


Question:
18. What occurs when an occupant travels a corridor and finds no exit

Answer:
A dead end exists.


Question:
19. Starting point used to measure travel distance to an exit

Answer:
The most remote point subject to occupancy.


Question:
20. Egress capacity

Answer:
The number of people allowed through any point of the means of egress.


Question:
21. All exits must have doors

Answer:
False; not every door is an exit.

Información del documento

Subido en
23 de octubre de 2026
Número de páginas
16
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$8.59

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
VictorGrades
5.0
(1)
Vendido
25
Seguidores
0
Artículos
2765
Última venta
2 semanas hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes