Examen

Exam_Elaborations_Irc_Building_Code_Certification_Evaluation_Exams.pdf

Document preview thumbnail
Vista previa 3 fuera de 21 páginas

Exam_Elaborations_Irc_Building_Code_Certification_Evaluation_E

Vista previa del contenido

EXAM ELABORATIONS IRC
BUILDING ACTUAL TEST WITH
VERIFIED SOLUTIONS


◉ The purpose of this code is to establish ___ requirements to
safeguard the public safety, health and general welfare. Answer:
Minimum


R101.3 Intent.


◉ Where, in any specific case, different sections of this code specify
different materials, methods of construction or other requirements,
the most ___ shall govern. Answer: Restrictive


R102.1 General.


◉ Where a referenced code or standard includes subject matter that
is within the scope of the IRC, the provisions of the ____ shall take
precedence. Answer: IRC


R102.4.2 Provisions in referenced codes and standards.

,◉ An alternative material or method shall be approved where the
proposed design is ___ and complies with the ____ of the code.
Answer: Satisfactory
Intent


R104.11 Alternative materials, design and methods of construction
and equipment.


◉ A finished or unfinished area, not considered a story, where the
occupiable space is enclosed by the roof assembly above and the
floor-ceiling assembly below is a ____. Answer: Habitable attic


R202 Definitions.


◉ Hot water is water at a temperature greater than or equal to ____ F.
Answer: 110 F
(Review and be familiar with all of the definitions in Chapter 2, it
will help taking the exam)


R202 Definitions (Definition of hot water).


◉ A wall supporting any vertical load in addition to its own weight is
a ____ -____ wall. Answer: Load-bearing

, R202 Definitions.


◉ The wind provisions of the IRC do not apply to the design of
buildings where the basic wind speed equals or exceeds ____ miles
per hour. Answer: 110 mph.


R301.2.1.1 Wind limitations and wind design required.


◉ What is the minimum uniformly distributed live load for habitable
attics and attics served with fixed stairs? Answer: 30 psf.


R301.5 Minimum Uniformly Distributed Live Loads.


◉ Wood structural panels with a minimum thickness of ____ inch and
maximum span of ____ feet shall be permitted for opening protection
in wind-borne debris regions. Answer: 7/16 in.
8
(Limited to one and two-story buildings)


R301.2.1.2


◉ The seismic provisions of the IRC apply to detached one- and two-
family dwellings in Seismic Design Categories ____. Answer: D0, D1
and D2

Información del documento

Subido en
15 de octubre de 2026
Número de páginas
21
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$16.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
4
Seguidores
0
Artículos
8342
Última venta
1 semana hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes