RTE 1401 Chapter 6 covers X-ray production, including characteristic and bremsstrahlung radiation, heat production, beam quantity and quality, kVp, mA, filtration, and half-value layer. Chapter 8 focuses on image production, differential absorption, attenuation, photoelectric and Compton interactions, image receptors, digital imaging, film-screen imaging, and fluoroscopy.

Vista previa del contenido

RTE 1401 Chapter 6


Question 1.
Binding energy for Tungsten K shell

ANSWER
69.5 keV



Question 2.
Binding energy for Tungsten L shell

ANSWER
12.1 keV



Question 3.
Binding energy for Tungsten M shell

ANSWER
2.82 keV



Question 4.
Binding energy for Tungsten N shell

ANSWER
0.6 keV



Question 5.
Binding energy for Tungsten O shell

ANSWER
0.08 keV



Question 6.
Binding energy for Tungsten P shell

ANSWER
0.008 keV



Question 7.
Discrete emission spectrum

ANSWER
illustrates characteristic x-ray production, x axis is the x-ray energy and the y axis is the number of each type of x-ray photon




1/7

, Question 8.
Characteristic photons

ANSWER
produced when outer-shell electrons fill inner-shell vacancies in atoms and are named for the shell being filled regardless of the shell involved representing
the energy variation depending on what shell is involved



Question 9.
Continuous emission spectrum

ANSWER
illustrates brems x-ray production, x axis is the energy, y axis is the number of photons, creates a bell shaped continuum



Question 10.
Primary beam

ANSWER
refers to the x-ray beam as it is upon exiting the collimator and exposing the patient



Question 11.
Remnant beam

ANSWER
refers to the x-ray beam that remains after interaction with the patient and is exiting the patient to expose the image receptor



Question 12.
transmitted photons

ANSWER
those exiting the patient without having interacted with anatomic structures



Question 13.
scattered photons

ANSWER
those that have lost energy and have been redirected after interacting with anatomic structures



Question 14.
Half value layer (HVL)

ANSWER
measurement for beam quality, defined as the thickness of absorbing material necessary to reduce the energy of the beam to one-half its original intensity



Question 15.
What is the normal HVL of diagnostic beams?

ANSWER
3-5 mm Al




2/7

Libro relacionado
 image
Editorial: 2019 ISBN: 9780323594486 Edición: Desconocido

Información del documento

Subido en
7 de octubre de 2026
Número de páginas
7
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$15.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
2
Seguidores
0
Artículos
2110
Última venta
1 mes hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes