• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 93 páginas
Examen

AMT MLT Exam 2025 – Medical Laboratory Technician Certification | 200 Practice Q&A with Detailed Rationales | Complete Study Guide

Document preview thumbnail
Vista previa 4 fuera de 93 páginas

Comprehensive AMT MLT Exam 2025 study guide for Medical Laboratory Technician certification preparation. Includes 200 practice questions with answers and detailed rationales covering core laboratory concepts, hematology, chemistry, microbiology, immunology, urinalysis, blood banking, laboratory safety, and specimen handling.

Vista previa del contenido

AMT MLT Exam Bank 2025 | 2 Accurate Currently
Testing Exam Versions – 200 Latest Q&A with
Rationales | Medical Laboratory Technician
Certification Study Guide




SECTION 1: BLOOD COLLECTION & PROCESSING (Questions
1–25)

Question 1
A phlebotomist collects a lavender-top tube for a CBC, then a light blue-top tube for
PT/INR. According to CLSI standards, is this order of draw acceptable?

A. Yes, lavender before light blue is the correct order
B. Yes, any order is acceptable as long as tubes are mixed
C. No, the light blue tube must be collected before the lavender tube
D. No, both tubes cannot be drawn in the same session

Answer: C
Rationale: Order of draw requires the light blue (sodium citrate) tube to be collected before
the lavender (EDTA) tube to prevent contamination with EDTA, which falsely prolongs
coagulation times. The standard order is: blood culture bottles → light blue → red/serum
→ green (heparin) → lavender (EDTA) → gray (fluoride/oxalate) .

,Question 2
The tourniquet should be applied approximately how many inches above the
venipuncture site?

A. 1–2 inches
B. 3–4 inches
C. 5–6 inches
D. 7–8 inches

Answer: B
Rationale: The tourniquet should be applied 3–4 inches above the puncture site to allow
adequate venous filling without causing excessive pressure or discomfort. Applying too
high may reduce effectiveness, while applying too low may interfere with the puncture site
.




Question 3
Which vein is the first choice for routine venipuncture in adult patients?

A. Basilic vein
B. Cephalic vein
C. Dorsal hand vein
D. Median cubital vein

Answer: D
Rationale: The median cubital vein is the preferred site because it is typically large, well-
anchored, less likely to roll, and has fewer adjacent nerves, reducing patient discomfort .

,Question 4
A lavender-top tube contains which additive and is used for which test?

A. Sodium citrate – coagulation studies
B. EDTA – hematology studies (CBC)
C. Heparin – chemistry tests
D. Sodium fluoride – glucose testing

Answer: B
Rationale: Lavender (purple) top tubes contain EDTA (ethylenediaminetetraacetic acid),
which chelates calcium and is used for hematology testing (CBC, blood smears) because it
preserves cell morphology .




Question 5
Which blood collection tube additive acts as an antiglycolytic agent to preserve
glucose?

A. Heparin
B. EDTA
C. Sodium fluoride
D. Sodium citrate

Answer: C
Rationale: Sodium fluoride inhibits glycolysis by blocking the enzyme enolase, preserving
glucose levels for up to 24 hours. Gray top tubes contain sodium fluoride and potassium
oxalate .

, Question 6
What is the minimum blood-to-anticoagulant ratio required for a light blue top tube?

A. 1:1
B. 2:1
C. 9:1
D. 4:1

Answer: C
Rationale: Light blue top tubes require a 9:1 blood-to-anticoagulant ratio. Underfilling or
overfilling can alter coagulation test results by affecting calcium binding and clot
formation .




Question 7
A technologist receives a blood specimen labeled with only the patient's last name. The
requisition lists full name and date of birth. The specimen is otherwise properly filled.
Which action is required?

A. Add the missing identifiers from the requisition and proceed with testing
B. Process the specimen because the last name matches the requisition
C. Call the floor and accept verbal confirmation of identity
D. Reject the specimen and request recollection with complete patient identification

Answer: D
Rationale: Laboratory specimens must have at least two unique patient identifiers that
match the requisition. A single name is insufficient; the specimen must be rejected and
recollected to prevent misidentification errors .

Información del documento

Subido en
30 de septiembre de 2026
Número de páginas
93
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$17.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TUTORMARY01
3.8
(5)
Vendido
28
Seguidores
0
Artículos
2370
Última venta
3 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes