The MOST specific information about the size and location of windows would be found in a -
Floor plan
What direction does heat flow? - Hot to cold
What are batter boards - stakes and ledger boards marking building lines
What is the MAXIMUM distance between a ventilating opening in an under-floor space and
each corner of the building? - 3 feet
What is NOT required in exterior nonbearing walls? - Load-bearing headers
A lengthwise grain separation between or through the growth rings of lumber is called a -
Shake (c 326)
The abbreviation "d" in "16d" means - Penny
Notches may not be located in the ____________ of a joist span - Middle 1/3
How should board and batten be installed? - 1 inch overlap 10d nails
, What is the maximum allowable notch in ceiling joists - 1/6 the depth of the member
How MUST rafters be framed to each other - Gusset plate (R802.3)
What is used to prevent buckling at points of high stress? - Squash blocks
Prior to the installation of wood floor how long for acclimation? - 4-5 days
Where do you start laying parquet flooring - Centerline
What is the first step in carpet installation? - Tackless strip
What type of nail is used in floor installation - 7d or 8d threaded/Cut steel
What should be applied to crevices in wood flooring? - Filling
What is the best nail for hardwood - Ring shank nail
What is the maximum size of a floor frame opening? - 5 sq ft (62) (R310.2.1)/ 4 ft header
joist (130) (R502.10)
The MOST specific information about the size and location of windows would be found in a -
Floor plan
What direction does heat flow? - Hot to cold
What are batter boards - stakes and ledger boards marking building lines
What is the MAXIMUM distance between a ventilating opening in an under-floor space and
each corner of the building? - 3 feet
What is NOT required in exterior nonbearing walls? - Load-bearing headers
A lengthwise grain separation between or through the growth rings of lumber is called a -
Shake (c 326)
The abbreviation "d" in "16d" means - Penny
Notches may not be located in the ____________ of a joist span - Middle 1/3
How should board and batten be installed? - 1 inch overlap 10d nails
, What is the maximum allowable notch in ceiling joists - 1/6 the depth of the member
How MUST rafters be framed to each other - Gusset plate (R802.3)
What is used to prevent buckling at points of high stress? - Squash blocks
Prior to the installation of wood floor how long for acclimation? - 4-5 days
Where do you start laying parquet flooring - Centerline
What is the first step in carpet installation? - Tackless strip
What type of nail is used in floor installation - 7d or 8d threaded/Cut steel
What should be applied to crevices in wood flooring? - Filling
What is the best nail for hardwood - Ring shank nail
What is the maximum size of a floor frame opening? - 5 sq ft (62) (R310.2.1)/ 4 ft header
joist (130) (R502.10)