• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 3 fuera de 22 páginas
Examen

Device Rac Exam Comprehensive Questions With Multiple Choices |Verified Revised Answers (New) Update Already Graded A+

Document preview thumbnail
Vista previa 3 fuera de 22 páginas

DEVICE RAC EXAM COMPREHENSIVE QUESTIONS WITH MULTIPLE CHOICES |VERIFIED REVISED ANSWERS (NEW) UPDATE ALREADY GRADED A+

Vista previa del contenido

DEVICE RAC EXAM COMPREHENSIVE QUESTIONS WITH MULTIPLE
CHOICES |VERIFIED REVISED ANSWERS (NEW) UPDATE ALREADY
GRADED A+



Which division would have primary jurisdiction over a vascular graft with an antibiotic based on primary
mode of action?

A. CDER

B. CBER

C. CDRH

D. OCP - (answer)C



A company wants to modify its legally marketed device such that the modification does not affect the
intended use or alter the fundamental scientific technology of the device. If the design outputs of the
modified device meet the design input requirements, this change would be best filed as a(n):

A. Special 510(k)

B. Abbreviated 510(k)

C. Traditional 510(k)

D. De novo 510(k) - (answer)A



Under the statutory violations, failure to meet 510(k) requirements for a device that is required to have a
510(k) and is in commercial distribution is considered to be:

A. Adulteration.

B. Improper use

C. Misbranded

D. Fraudulent - (answer)C



A company's competitor is marketing a Class II suture which dissolves during the third week of use. The
company's current product has to be removed by a physician. However, a change in weaving
configuration gives this product the same dissolving time as the competitor's. When can the company's
new suture be marketed?

,DEVICE RAC EXAM COMPREHENSIVE QUESTIONS WITH MULTIPLE
CHOICES |VERIFIED REVISED ANSWERS (NEW) UPDATE ALREADY
GRADED A+




A. This requires a new 510(k) since significant change in product instructions might

affect efficacy.

B. After submission in a periodic report

C. After reporting clinical studies in an annual report

D. After submission of labeling change - (answer)A



Which of the following is exempt from GMP/QSR regulations?

A. Remanufacturers

B. Custom device manufacturers

C. Repackagers

D. Component manufacturers - (answer)D



A physician reports to a manufacturer that a patient was hospitalized with acute sepsis after treatment
with an approved device. This side effect is not listed in the package insert. This event must be reported
by the manufacturer to FDA no later than:

A. 5 calendar days

B. 15 calendar days

C. 30 calendar days

D. The next quarterly or annual report - (answer)C



If a device failure is occurring with greater than expected frequency and investigation of the problem
implicates improper use by the end user, which of the following typically occurs?

A. The labeling is revised.

B. The product is recalled.

, DEVICE RAC EXAM COMPREHENSIVE QUESTIONS WITH MULTIPLE
CHOICES |VERIFIED REVISED ANSWERS (NEW) UPDATE ALREADY
GRADED A+



C. The product is redesigned.

D. A "Dear Doctor" letter is issued. - (answer)A



A handling and storage system for medical devices must always include:

A. Procedures for rotation of stock

B. Separate rooms or cages for release and quarantine products

C. Procedures for receipt and transfer of product

D. Environmentally controlled areas for products with shelf life - (answer)C



You have modified your 510(k) cleared device with a special 510(k). In which of the following cases
would you need to create a new listing for the device?

A. You have added new sizes and shapes in the product portfolio.

B. You have changed the material composition of the device.

C. You have changed the package of the device.

D. None of the above. - (answer)D



According to the QSR, when an investigation of a complaint is conducted all of the following are
requirements for inclusion in the record of the investigation EXCEPT:

A. The dates and results of the investigation

B. The nature and details of the complaint

C. Changes in procedures correcting quality problems

D. Any reply to the complainant - (answer)C



The QSR calls for the manufacturer of finished devices to carry out all of the following EXCEPT:

Información del documento

Subido en
28 de septiembre de 2026
Número de páginas
22
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$22.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MegaPlus
5.0
(490)
Vendido
4195
Seguidores
1
Artículos
501
Última venta
16 horas hace

Reseñas de compradores verificados




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes