⩥ Lateral resolution is dependent on? Answer: beam diameter


⩥ Where does the beam of an unfocused transducer diverge? Answer:
Fraunhofer zone


⩥ Reverberation artifacts are a result of Answer: two or more strong
reflecting surfaces


⩥ True/False: Grating lobes are essential for the proper operation of a
linear phased array. Answer: False


⩥ True/False: Electronically steered scanners always produce higher
resolution images than do mechanically steered scanners. Answer: False


⩥ True/False: An annular array scanner uses mechanical beam steering.
Answer: True

,⩥ True/False: A linear sequenced array cannot be dynamically focused.
Answer: False


⩥ registration or B-mode alignment Answer: Which AIUM test object
function utilizes all the groups of wires in the AIUM 100 mm test
object?


⩥ axial resolution Answer: Which AIUM test object function utilizes the
A group of wires in the AIUM 100 mm test object?


⩥ lateral resolution Answer: Which AIUM test object function utilizes
the B group of wires in the AIUM 100 mm test object?


⩥ dead zone Answer: Which AIUM test object function utilizes the D
group of wires in the AIUM 100 mm test object?


⩥ depth calibration Answer: Which AIUM test object function utilizes
the C or E groups of wires in the AIUM 100 mm test object?


⩥ What happens to axial resolution when spatial pulse length is
decreased? Answer: improves


⩥ How much will a 3.5 MHz pulse be attenuated after passing through 2
cm of soft tissue? Answer: 3.5 dB

,⩥ Propagation speed errors result in Answer: improper axial position


⩥ Enhancement is caused by Answer: weakly attenuating structures


⩥ The Doppler shift frequency is Answer: directly proportional to the
velocity of the reflector


⩥ The number of frames per second necessary for a real-time image to
be flicker free is Answer: more than 15


⩥ True/False: The SPTA intensity will always be larger than the SATA
intensity. Answer: True


⩥ The intensity of the ultrasound beam is usually greater at the focal
zone because of Answer: the smaller beam diameter


⩥ If the amplitude is doubled, the intensity is Answer: quadrupled


⩥ The attenuation for soft tissue is Answer: increased with tissue
thickness

, ⩥ The acoustic impedance of the matching layer Answer: can be chosen
to improve transmission into the body


⩥ True/False: In a pulse-echo system, the quality factor should be made
as large as possible. Answer: False


⩥ True/False: The beam diameter is constant in the near zone. Answer:
False


⩥ The operating frequency is dependent on Answer: thickness of the
crystal


⩥ The period of an ultrasound wave is Answer: the time of one
wavelength


⩥ The dynamic range of a system is Answer: the ratio of smallest to
largest power level that the system can handle


⩥ True/False: The intensity of an ultrasonic beam can be measured with
radiation force balance. Answer: True


⩥ Increasing the pulse repetition period Answer: increases the maximum
depth that can be imaged

Información del documento

Subido en
18 de septiembre de 2026
Número de páginas
81
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$16.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Vendido
2
Seguidores
0
Artículos
2232
Última venta
1 mes hace




Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes