• ¿Documento equivocado? Cámbialo gratis
  • Escrito por estudiantes que aprobaron
  • Inmediatamente disponible después del pago
  • Leer en línea o como PDF
Vender
¿Dónde estudias?
Tu idioma
Document preview thumbnail
Vista previa 4 fuera de 82 páginas
Examen

Ohio (OH) Maintenance Technician Exam | Latest Verified Questions and Detailed Answers

Document preview thumbnail
Vista previa 4 fuera de 82 páginas

OVERVIEW DESCRIPTION: This Comprehensive set of multiple choice questions is designed for the Ohio Maintenance Technician Exam, a multiple-choice assessment that evaluates hands-on competency, safety protocols, and diagnostic skills across residential, commercial, and industrial building maintenance. The exam covers electrical systems, including lockout/tagout safety rules, multimeter use, breaker overloads, and GFCI requirements; plumbing systems, including soldering copper lines, leak repair, drain clearing, and water heater safety relief valves; HVAC and mechanical systems, including basic refrigeration cycles, thermostat wiring, blower motor service, and filter replacement; and general maintenance and safety, including OSHA compliance, PPE usage, basic carpentry, patching, and unit turnover procedures.

Vista previa del contenido

1|Page



Ohio (OH) Maintenance Technician Exam | Latest Verified
Questions and Detailed Answers

OVERVIEW DESCRIPTION:
This Comprehensive set of multiple choice questions is designed for the Ohio Maintenance
Technician Exam, a multiple-choice assessment that evaluates hands-on competency, safety
protocols, and diagnostic skills across residential, commercial, and industrial building
maintenance. The exam covers electrical systems, including lockout/tagout safety rules,
multimeter use, breaker overloads, and GFCI requirements; plumbing systems, including
soldering copper lines, leak repair, drain clearing, and water heater safety relief valves;
HVAC and mechanical systems, including basic refrigeration cycles, thermostat wiring,
blower motor service, and filter replacement; and general maintenance and safety,
including OSHA compliance, PPE usage, basic carpentry, patching, and unit turnover
procedures.

QUESTION 1
According to OSHA lockout/tagout (LOTO), what is the first step before servicing

equipment?
A) Lock the main disconnect

B) Notify affected employees
C) Test the circuit

D) Remove the fuses

CORRECT ANSWER: B


EXPERT RATIONALE: Affected employees must be notified before shutdown so they
know not to restart or use the equipment. Locking and testing occur after proper

shutdown and isolation.

QUESTION 2
When using a multimeter to measure resistance, what must be done first?

,2|Page


A) Set the meter to AC volts

B) De-energize the circuit
C) Connect the leads to the current jacks

D) Increase the range to maximum

CORRECT ANSWER: B


EXPERT RATIONALE: Resistance measurements require a de-energized circuit to prevent
meter damage and electric shock. The ohmmeter uses its own internal battery to

measure resistance.

QUESTION 3

Which location does NOT require GFCI protection in a dwelling unit?
A) Bathroom

B) Garage
C) Bedroom

D) Kitchen countertop

CORRECT ANSWER: C


EXPERT RATIONALE: GFCI protection is required in bathrooms, garages, kitchen
countertops, outdoors, and other damp locations. Bedrooms require AFCI protection

instead.

QUESTION 4

A 20-amp circuit breaker repeatedly trips when multiple portable heaters are connected.
What is the most likely cause?

A) Short circuit
B) Circuit overload

,3|Page


C) Ground fault

D) Open neutral

CORRECT ANSWER: B


EXPERT RATIONALE: Multiple heaters draw more current than the breaker rating,
causing an overload. A short circuit or ground fault would typically trip instantly.


QUESTION 5
In standard 120-volt AC wiring, what color is the neutral conductor?

A) Black
B) Red

C) White or gray
D) Green


CORRECT ANSWER: C

EXPERT RATIONALE: White or gray identifies the grounded neutral conductor. Green or

bare copper is reserved for equipment grounding.

QUESTION 6

What is the standard voltage for a general-purpose receptacle in U.S. residential wiring?
A) 120 volts

B) 240 volts
C) 277 volts

D) 480 volts

CORRECT ANSWER: A


EXPERT RATIONALE: General-purpose residential receptacles are normally 120 volts.
Larger appliances such as electric ranges and dryers use 240 volts.

, 4|Page


QUESTION 7

Which statement about lockout/tagout is TRUE?
A) A tag may substitute for a lock

B) A lockout device must be applied by an authorized employee
C) Only a supervisor can remove a lock

D) Tags are sufficient for electrical isolation

CORRECT ANSWER: B


EXPERT RATIONALE: Lockout devices must be applied by an authorized employee and
remain under that employee’s control. Tags alone do not provide physical restraint

against startup.

QUESTION 8

When testing a live electrical circuit with a multimeter, what setting should be selected
first?

A) DC volts
B) AC volts

C) Resistance
D) Current


CORRECT ANSWER: B

EXPERT RATIONALE: Building power circuits are AC, so the meter must be set to AC

voltage. Using resistance or current settings on a live circuit can damage the meter.

QUESTION 9

A Class A GFCI is designed to trip when leakage current exceeds approximately:
A) 1 mA
B) 5 mA

Información del documento

Subido en
12 de septiembre de 2026
Número de páginas
82
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$75.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
VerifiedSets
3.7
(7)
Vendido
38
Seguidores
1
Artículos
1998
Última venta
5 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes