Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 14 páginas
Examen

S13 standpipe test Questions And Answers| Well Elaborated Solutions|

Document preview thumbnail
Vista previa 2 fuera de 14 páginas

S13 standpipe test Questions And Answers| Well Elaborated Solutions| Unlined Hose - ANSWER -A hose consisting of only a woven jacket that is usually of linen yarns and is of such quality that the yarn swells when wet, tending to seal the hose. Hose Size - ANSWER -An expression of the internal diameter of the hose. Hose Station - ANSWER -a combination of a hose rack, hose nozzle, hose, and hose connection. In Service - ANSWER -The status of hose stored in a hose house, on a rack or reel, or on a fire apparatus that is available and ready for immediate use at an incident. In Storage - ANSWER -A hose that is not readily available for use because it is not at the scene of an incident and not loaded on a vehicle that can transport it to the scene. In Use - ANSWER -Hose being used during fire suppression or during training. Impairment Coordinator - ANSWER -The person responsible for ensuring that proper safety precautions are taken when a fire protection system is placed out of service. Labeled - ANSWER -Equipment or materials to which has been attached a label, symbol or other identifying mark. Listed Device - ANSWER -A fire protection component that has been tested to perform under parameters specified for its use by a nationally recognized testing agency. Manual Standpipe - ANSWER -Standpipe system that relies exclusively on the fire department connection to supply the system demand. Master Pressure Reducing Valve - ANSWER -A pressure reducing valve installed to regulate pressures in an entire fire protection system and/or standpipe system zone. Main Drain - ANSWER -The primary drain connection located on the system riser and also utilized as a flow test connection for the automatic sprinkler system. Nozzles - ANSWER -A device for use in applications requiring special water discharge patterns, directional spray, or other unusual discharge characteristics. Occupant-Use Hose - ANSWER -Fire Hose designed to be used by the building's occupants to fight incipient fires prior to the arrival of trained fire fighters or fire brigade members. Out of service system - ANSWER -A fire protection system that is not fully functional; or whose operation is impaired or is otherwise not in good working order. Personal Supervision - ANSWER -Supervision by the holder of a department certificate who is required to be personally present on the premises, or other proximate location acceptable to the department, while the duties for which the certificate is required is being performed Pounds per square inch (PSI) - ANSWER -a unit of pressure measuring force per unit area. Pressure Control Valve - ANSWER -A pilot operated pressure reducing valve that may be used with a fire or booster pump designed for preventing the water supply pressure from dropping below a set pressure. Pressure-Reducing Valve - ANSWER -A valve designed for the purpose of reducing the downstream water pressure under both flowing (residual) and non flowing (static) conditions. Pressure Regulating Device - ANSWER -A device designed for the purpose of reducing, regulating controlling, or restricting water pressure. Pressure Restricting Device - ANSWER -A valve or device designed for the purpose of reducing the downstream water pressure under flowing (residual) conditions only. Pressure Relief Valve - ANSWER -A valve designed for the purpose of releasing excess air or water pressure from the Fire Protection Piping System. Pressure relief valve is not a pressure reducing valve. Pressure Tank - ANSWER -A tank using air pressure to supplying water for water-based fire protection systems. Tank contents to be maintained at one third air to two thirds water. Service Test - ANSWER -Hydrostatic test conducted by users on all in-service hose to determine suitability for continued service. Standpipe, Multi-Zone - ANSWER -A standpipe system that is vertically subdivided as required by the construction codes, including the Building Code, into zones to limit the maximum operating pressure in the system. Each zone will have its own individual automatic water supply. Standpipe System - ANSWER -An arrangement of piping, valves, hose connections, and allied equipment installed in a building or structure, with the hose connections located in such a manner that water can be discharged in streams or spray. Combination Standpipe and Sprinkler System - ANSWER -A system where the fire protection piping services both outlets for fire department use and outlets for automatic sprinklers. Static Pressure - ANSWER -The measurement of system pressure under non flow conditions Strainer - ANSWER -A device capable of removing from the water all solids of sufficient size that are obstructing water spray nozzles. Supervisory signal - ANSWER -signal indicating the need for action in connection with the supervision of guard tours, fire extinguishing systems or equipment, fire alarm systems or the maintenance features of related systems. Supervisory signal-initiating device - ANSWER -an initiating device, such as a valve supervisory switch, water level indicator, or low-air pressure switch on a dry-pipe system, that triggers a supervisory signal.

Vista previa del contenido

S13 standpipe test Questions And
Answers| Well Elaborated Solutions|
Unlined Hose - ANSWER -A hose consisting of only a woven jacket that is
usually of linen yarns and is of such quality that the yarn swells when wet, tending
to seal the hose.

Hose Size - ANSWER -An expression of the internal diameter of the hose.

Hose Station - ANSWER -a combination of a hose rack, hose nozzle, hose, and
hose connection.

In Service - ANSWER -The status of hose stored in a hose house, on a rack or
reel, or on a fire apparatus that is available and ready for immediate use at an
incident.

In Storage - ANSWER -A hose that is not readily available for use because it is
not at the scene of an incident and not loaded on a vehicle that can transport it to
the scene.

In Use - ANSWER -Hose being used during fire suppression or during training.

Impairment Coordinator - ANSWER -The person responsible for ensuring that
proper safety precautions are taken when a fire protection system is placed out of
service.

Labeled - ANSWER -Equipment or materials to which has been attached a label,
symbol or other identifying mark.

Listed Device - ANSWER -A fire protection component that has been tested to
perform under parameters specified for its use by a nationally recognized testing
agency.

Manual Standpipe - ANSWER -Standpipe system that relies exclusively on the
fire department connection to supply the system demand.

, Master Pressure Reducing Valve - ANSWER -A pressure reducing valve installed
to regulate pressures in an entire fire protection system and/or standpipe system
zone.

Main Drain - ANSWER -The primary drain connection located on the system
riser and also utilized as a flow test connection for the automatic sprinkler system.

Nozzles - ANSWER -A device for use in applications requiring special water
discharge patterns, directional spray, or other unusual discharge characteristics.

Occupant-Use Hose - ANSWER -Fire Hose designed to be used by the building's
occupants to fight incipient fires prior to the arrival of trained fire fighters or fire
brigade members.

Out of service system - ANSWER -A fire protection system that is not fully
functional; or whose operation is impaired or is otherwise not in good working
order.

Personal Supervision - ANSWER -Supervision by the holder of a department
certificate who is required to be personally present on the premises, or other
proximate location acceptable to the department, while the duties for which the
certificate is required is being performed

Pounds per square inch (PSI) - ANSWER -a unit of pressure measuring force per
unit area.

Pressure Control Valve - ANSWER -A pilot operated pressure reducing valve that
may be used with a fire or booster pump designed for preventing the water supply
pressure from dropping below a set pressure.

Pressure-Reducing Valve - ANSWER -A valve designed for the purpose of
reducing the downstream water pressure under both flowing (residual) and non
flowing (static) conditions.

Pressure Regulating Device - ANSWER -A device designed for the purpose of
reducing, regulating controlling, or restricting water pressure.

Pressure Restricting Device - ANSWER -A valve or device designed for the
purpose of reducing the downstream water pressure under flowing (residual)
conditions only.

Información del documento

Subido en
6 de septiembre de 2026
Número de páginas
14
Escrito en
2026/2027
Tipo
Examen
Contiene
Preguntas y respuestas
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
TheExamMaestro
3.6
(18)
Vendido
155
Seguidores
5
Artículos
3771
Última venta
5 días hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes