ARIZONA (AZ) CR65 GLAZING PRACTICE EXAM QUESTIONS AND CORRECT SOLUTIONS JUST RELEASED
THIS YEAR………...
Core Domains:
1. Arizona Registrar of Contractors (ROC) Laws and Business Practices
2. Safety Glazing Requirements and Building Codes (IBC/IRC)
3. Glass Types, Properties, and Manufacturing
4. Glazing Installation Systems and Methods
5. Sealants, Gaskets, and Framing Systems
6. OSHA Safety Standards and Personal Protective Equipment (PPE)
7. Tools, Estimating, and Project Management
8. Insulated Glass Units (IGUs) and Energy Efficiency
9. Glass Handling, Storage, and Maintenance
10. Ethics, Contracts, and Professional Standards
Introduction:
This comprehensive examination is designed to rigorously assess the competencies required for successful licensure
as a CR65 Glazing Contractor in the state of Arizona. It evaluates a candidate's foundational knowledge of glazing
systems, applied professional skills in glass installation and safety, and critical decision-making abilities in complex
project scenarios. The assessment is structured using multiple-choice questions and scenario-based inquiries to
gauge not only theoretical understanding but also the practical application of building codes, safety regulations,
and industry best practices. Success in this exam demonstrates a candidate's readiness to navigate the multifaceted
challenges of the glazing trade, prioritizing safety, code compliance, and professional excellence in both residential
and commercial applications.
,SECTION ONE: QUESTIONS 1 – 100
1. A CR65 contractor in Arizona is primarily licensed to perform which of the following?
A. Only residential window glass replacement
B. Any type of glass installation, including structural storefronts and curtain walls
C. Glass installation but not metal framing
D. Only automotive glass installation
🟢 B. Any type of glass installation, including structural storefronts and curtain walls
🔴 RATIONALE: The CR65 Glazing classification authorizes the installation of glass, metal framing, storefronts,
curtain walls, mirrors, glass doors, and related hardware in both residential and commercial buildings.
2. Under Arizona Revised Statutes, what is the minimum financial responsibility requirement (surety bond or
assigned account) for a CR65 contractor?
A. $10,000
B. $25,000
C. $50,000
D. $100,000
🟢 C. $50,000
🔴 RATIONALE: Arizona requires a $50,000 financial responsibility (surety bond or assigned account) for the
CR65 license class.
3. Which entity directly administers and enforces the CR65 licensing requirements in Arizona?
,A. Arizona Department of Building Safety
B. Arizona Registrar of Contractors (AZ ROC)
C. International Code Council (ICC)
D. City of Phoenix Planning Department
🟢 B. Arizona Registrar of Contractors (AZ ROC)
🔴 RATIONALE: The Arizona Registrar of Contractors (AZ ROC) is the state agency responsible for licensing and
regulating contractors, including the CR65 Glazing classification.
4. According to Arizona ROC statutes, how many years of relevant work experience are required to qualify
for a CR65 license?
A. One year
B. Two years
C. Four years
D. Five years
🟢 C. Four years
🔴 RATIONALE: A.R.S. § 32-1121 and ROC rules generally require four years of relevant, verified journeyman-
level experience within the past ten years to qualify for a CR65 license.
5. Which of the following activities is NOT permitted under an Arizona CR65 glazing license?
A. Installing tempered glass in a storefront
B. Applying window film to existing glass
, C. Installing structural steel beams for a curtain wall
D. Installing glass-holding members such as glazing beads
🟢 C. Installing structural steel beams for a curtain wall
🔴 RATIONALE: The CR65 license authorizes installation of glass, window film, weatherproofing, caulking,
sealants, adhesives, and glass-holding members. Installing structural steel components requires a different
contractor classification (e.g., structural steel or general contracting license).
6. What is the minimum thickness of tempered glass required for use in hazardous locations per the
International Building Code (IBC)?
A. 1/8 inch
B. 3/16 inch
C. 1/4 inch
D. 3/8 inch
🟢 C. 1/4 inch
🔴 RATIONALE: The IBC requires tempered safety glass in hazardous locations to be a minimum of 1/4 inch
(6mm) thick to provide adequate impact resistance and ensure occupant safety.
7. Which type of glass is required by code in shower enclosures?
A. Plate glass
B. Annealed glass
C. Wired glass
THIS YEAR………...
Core Domains:
1. Arizona Registrar of Contractors (ROC) Laws and Business Practices
2. Safety Glazing Requirements and Building Codes (IBC/IRC)
3. Glass Types, Properties, and Manufacturing
4. Glazing Installation Systems and Methods
5. Sealants, Gaskets, and Framing Systems
6. OSHA Safety Standards and Personal Protective Equipment (PPE)
7. Tools, Estimating, and Project Management
8. Insulated Glass Units (IGUs) and Energy Efficiency
9. Glass Handling, Storage, and Maintenance
10. Ethics, Contracts, and Professional Standards
Introduction:
This comprehensive examination is designed to rigorously assess the competencies required for successful licensure
as a CR65 Glazing Contractor in the state of Arizona. It evaluates a candidate's foundational knowledge of glazing
systems, applied professional skills in glass installation and safety, and critical decision-making abilities in complex
project scenarios. The assessment is structured using multiple-choice questions and scenario-based inquiries to
gauge not only theoretical understanding but also the practical application of building codes, safety regulations,
and industry best practices. Success in this exam demonstrates a candidate's readiness to navigate the multifaceted
challenges of the glazing trade, prioritizing safety, code compliance, and professional excellence in both residential
and commercial applications.
,SECTION ONE: QUESTIONS 1 – 100
1. A CR65 contractor in Arizona is primarily licensed to perform which of the following?
A. Only residential window glass replacement
B. Any type of glass installation, including structural storefronts and curtain walls
C. Glass installation but not metal framing
D. Only automotive glass installation
🟢 B. Any type of glass installation, including structural storefronts and curtain walls
🔴 RATIONALE: The CR65 Glazing classification authorizes the installation of glass, metal framing, storefronts,
curtain walls, mirrors, glass doors, and related hardware in both residential and commercial buildings.
2. Under Arizona Revised Statutes, what is the minimum financial responsibility requirement (surety bond or
assigned account) for a CR65 contractor?
A. $10,000
B. $25,000
C. $50,000
D. $100,000
🟢 C. $50,000
🔴 RATIONALE: Arizona requires a $50,000 financial responsibility (surety bond or assigned account) for the
CR65 license class.
3. Which entity directly administers and enforces the CR65 licensing requirements in Arizona?
,A. Arizona Department of Building Safety
B. Arizona Registrar of Contractors (AZ ROC)
C. International Code Council (ICC)
D. City of Phoenix Planning Department
🟢 B. Arizona Registrar of Contractors (AZ ROC)
🔴 RATIONALE: The Arizona Registrar of Contractors (AZ ROC) is the state agency responsible for licensing and
regulating contractors, including the CR65 Glazing classification.
4. According to Arizona ROC statutes, how many years of relevant work experience are required to qualify
for a CR65 license?
A. One year
B. Two years
C. Four years
D. Five years
🟢 C. Four years
🔴 RATIONALE: A.R.S. § 32-1121 and ROC rules generally require four years of relevant, verified journeyman-
level experience within the past ten years to qualify for a CR65 license.
5. Which of the following activities is NOT permitted under an Arizona CR65 glazing license?
A. Installing tempered glass in a storefront
B. Applying window film to existing glass
, C. Installing structural steel beams for a curtain wall
D. Installing glass-holding members such as glazing beads
🟢 C. Installing structural steel beams for a curtain wall
🔴 RATIONALE: The CR65 license authorizes installation of glass, window film, weatherproofing, caulking,
sealants, adhesives, and glass-holding members. Installing structural steel components requires a different
contractor classification (e.g., structural steel or general contracting license).
6. What is the minimum thickness of tempered glass required for use in hazardous locations per the
International Building Code (IBC)?
A. 1/8 inch
B. 3/16 inch
C. 1/4 inch
D. 3/8 inch
🟢 C. 1/4 inch
🔴 RATIONALE: The IBC requires tempered safety glass in hazardous locations to be a minimum of 1/4 inch
(6mm) thick to provide adequate impact resistance and ensure occupant safety.
7. Which type of glass is required by code in shower enclosures?
A. Plate glass
B. Annealed glass
C. Wired glass