Escrito por estudiantes que aprobaron Inmediatamente disponible después del pago Leer en línea o como PDF ¿Documento equivocado? Cámbialo gratis 4,6 TrustPilot
logo-home
Document preview thumbnail
Vista previa 2 fuera de 8 páginas
Examen

Exam Bank: Portage Learning BIOD 171 Essential Microbiology Module 3 Exam | 2025 Updated Edition with 100% Verified Answers

Document preview thumbnail
Vista previa 2 fuera de 8 páginas

BIOD 171 Module 3 Exam Bank (Latest-2025) / BIOD171 Essential Microbiology with Lab: Portage Learning - This Exam Bank features multiple complete sets of the most current exam questions, reviewed and updated to reflect the 2025 version of BIOD171 as offered through Portage Learning. With over two full exam sets, this resource offers a broader and more comprehensive preparation tool. Students can study with confidence, knowing they’re reviewing the latest question formats and lab-related content likely to appear in their module assessments.

Vista previa del contenido

M3: Exam - Requires Respondus LockDown
Browser + Webcam
Due No due date Points 100 Questions 23
Time Limit 60 Minutes Requires Respondus LockDown Browser




Questions and Answers:
# Question Points Answer
1 a. A micrometer is defined as: 5 a. 10-6
- 10-3
- 10-6 b. C. 10-9
- 10-9
- 10-12

b. A nanometer is defined as:
A. 10-3
B. 10-6




ta
C. 10-9
D. 10-12

2 a. Resolution and contrast are two critical 10 a. Resolution refers to the distance between
da
factors that influence your ability to see two objects at which the objects still can be
an object. Explain each. seen as separate. Poor or low resolution means
two (or more) objects may appear as one.

Contrast is the difference in light absorbance
on

between two objects. Poor contrast gives a high
background and makes the visualization of
multiple objects difficult. For instance, trying to
identify 2 dark colored objects at night (low
light = low contrast) versus the same 2 objects
in the middle of a sunny afternoon (bright light
ta


against 2 dark objects = high contrast).

3 a. Assuming a constant (non-adjustable) 3 a. Iris diaphragm
light source power, identify the part of the (The iris controls the amount of light that
da




microscope you would adjust to limit the passes through the sample and into the
amount of light entering the microscope. objective lens. Thus, it can be adjusted (opened
Select all that apply. or closed) to alter the amount of light).
- Eye piece
- Objective b. Objective
- Condenser (Only the oculars (eyepiece) and the objectives
- Iris diaphragm contribute to the magnification of the sample.
Since the eyepiece is fixed, only the objectives
b. Assuming a fixed ocular, identify the could be altered).
part of the microscope you would adjust
to enhance the magnification of a sample.
- Objective
- Condenser
- Iris diaphragm
- Eye piece

, M3: Exam - Requires Respondus LockDown
Browser + Webcam
Due No due date Points 100 Questions 23
Time Limit 60 Minutes Requires Respondus LockDown Browser




# Question Points Answer
4 a. What is the total magnification (relative 5 a. 60 x 10 = 600x magnification
to your eye) of a sample imaged with a
60x objective and a 10x eyepiece? Show
your math.

5 a. True or False: A cell that is adherent, 3 a. False
flat (thin), and unstained is easily (Adherent, flat cells are almost invisible due to
identified using bright field microscopy. the limits on both resolution and contrast).

6 a. Which of the following could be seen 3 a.
clearly by the unaided eye? Select all that Protozoa with diameter of 150 μm




ta
apply. Skin cell with diameter of 1500 μm
- Protozoa with diameter of 150 μm (The unaided eye can, on average, clearly
- Skin cell with diameter of 1500 μm resolve objects > 100 μm).
- Virus with a diameter of 0.2 μm
da
- Bacteria with diameter of 24 μm b.
Bacteria with diameter of 24 μm
b. Which of the following could NOT be Virus with a diameter of 0.2 μm
seen clearly by the unaided eye? Select all Protozoa with diameter of 150 μm
that apply.
on

- Bacteria with diameter of 24 μm Sidenote: Portage is so lousy with their question
- Virus with a diameter of 0.2 μm setting. Not sure how they deemed both answers
- Protozoa with diameter of 150 μm in a. and b. as correct. Yet, their notes say 200μm
- Skin cell with diameter of 1500 μm (we’re basically doomed either way you answer
lol)
ta


7 a. Label the following unmarked 10 a.
microscope components (numbered 1=F
arrows) by matching it with the 2=D
components provided (letters). 3=B
da




4=G
5=A
6=H

Información del documento

Subido en
31 de agosto de 2026
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas
$19.99

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
dataondata
4.3
(235)
Vendido
869
Seguidores
15
Artículos
51
Última venta
1 hora hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes